Product Introduction:
Special-configuration probe with 90° miniature coax connector and NEPSI certification for tight radial clearances inside Chinese turbines and compressors.
Product Introduction:
Shorter 4 m system variant certified for Chinese installations. Ideal when the driver cabinet is located close to the machine and space is limited.
Product Introduction:
China-market version of 330180-91-05, factory-certified to NEPSI Ex ia IIC T4 Ga and GB/T standards. Provides identical electrical performance while simplifying customs clearance and on-site acceptance in Chinese hazardous-area plants.
Technical Specifications:
System Length: 9.0 m
Mounting: DIN-rail or panel
Supply: –24 VDC
Output: 7.87 V/mm
Operating Temperature: –40 °C to +120 °C
Approvals: NEPSI Ex ia IIC T4 Ga, Ex ia IIIC T135 °C Da, GB/T 13384-2018
Product Introduction:
The 330180-91-05 is the 9 m system-length eddy-current driver that converts probe gap into a precision DC voltage. It is DIN-rail mounted and carries global Ex approvals for use in hazardous areas. The unit delivers API 670 compliant linearity and interchangeability while withstanding the temperature extremes found in large turbines and compressors.
Product Introduction:
DIN-rail version of the 9 m system for high-density cabinets. Identical electrical specs to 330180-90-00 but with integral DIN-rail clip.