Yokogawa YF108-AAUE4D-S3S3 DigitalYEWFLO Vortex Flowmeter
Technical Specifications:
- Measured Media: Liquid, gas, steam (no multiphase flow or viscous fluids).
- Accuracy: ±0.75% of reading (liquid); ±1% of reading (gas, steam).
- Repeatability: ±0.2% of reading.
- Process Temperature: -29~250°C (standard).
- Process Pressure: Up to 10MPa.
- Output: 4-20mA DC, pulse, HART 7.0 (AAUE4D option).
- Power Supply: 10.5-42V DC.
- Connection: Wafer (S3S3 option), stainless steel tag plate.