Yokogawa UR5AG3-500N-1S E-2SA-N
Working Principle: The UR5AG3 uses an electromechanical pen-drive system. Input signals (voltage, current, thermocouple, RTD) are converted by internal circuitry and drive a servo motor with pen arm across a moving chart paper. The pen deflects proportionally to the input signal, creating a continuous analog trace. The chart paper advances at selectable speeds (25mm/h to 600mm/h). Alarm contacts close when input exceeds preset thresholds.
Detailed content
Model Breakdown:
| Code | Meaning |
|---|---|
| UR5 | UR5 Series Paper Recorder |
| A | Alarm Function Included |
| G | 3-Channel Input |
| 3 | Model Variant |
| 500N | 500 mm Chart Width (N = Standard Scale) |
| 1S | Single Pen per Channel (1 pen, Single trace) |
| E | Input Type E (Universal: Voltage, Current, TC, RTD, Contact) |
| 2SA | Chart Paper Type 2SA (100 mm × 500 mm, 1-day or 7-day roll) |
| N | No Special Option |
Technical Specifications:
| Parameter | Specification |
|---|---|
| Number of Channels | 3 Channels |
| Chart Width | 500 mm (19.7 inches) |
| Recording Speed | 25, 50, 100, 120, 250, 600 mm/h (selectable) |
| Pen Type | Single Pen (1S) — One pen per channel |
| Input Signal (Type E) | DC Voltage: 1–5 V, DC Current: 4–20 mA, TC: J, K, T, E, R, S, B, N; RTD: Pt100, JPt100; Contact: ON/OFF |
| Accuracy | ±0.5% of Full Scale (F.S.) |
| Alarm Output | 2 Alarm Outputs per Channel (Total 6 alarm contacts), SPDT Relay, 250V AC / 3A |
| Alarm Accuracy | ±1% of Set Point |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Power Consumption | Approximately 30 VA |
| Operating Temperature | 0°C to +50°C (32°F to +122°F) |
| Operating Humidity | 30% to 85% RH (non-condensing) |
| Chart Paper | Type 2SA: 100 mm × 500 mm, 1-day or 7-day roll (100 sheets per roll) |
| Dimensions (W×H×D) | Approximately 270 × 270 × 280 mm (10.6 × 10.6 × 11.0 inches) |
| Weight | Approximately 5.5 kg (12.1 lbs) |
| Protection Rating | IP54 (Front Panel) |
| Certification | UL, CSA, CE |
Material Composition:
- Housing: Flame-retardant ABS Resin (White/Light Gray)
- Chart Cover: Transparent Polycarbonate (Smoke-tinted)
- Pen Arm: Stainless Steel with Ink Pen (Black/Red/Blue ink cartridges available)
- Internal Mechanism: Aluminum Die-Cast Gears, Stepper/Servo Motor
- Terminal Block: Screw-type terminals (for field wiring)
Structural Features:
- Wall-mount or panel-mount design
- Transparent hinged front cover for paper loading without stopping recording
- Built-in chart paper cutter
- Alarm relay terminals on rear panel
- Zero-point and span adjustment knobs on front panel
Applicable Industries:
- Water & Wastewater Treatment
- HVAC & Building Automation
- Food & Beverage Processing
- Pharmaceutical Manufacturing
- Chemical Plants (Non-hazardous areas)
- Power Generation (Auxiliary Systems)
Advantages & Highlights:
- Pure analog recording — no data loss during power failure
- 3-channel simultaneous recording on 500 mm wide chart
- Built-in alarm contacts — no external relay required
- Wide input compatibility (Type E) — accepts TC, RTD, mA, V, and contact inputs
- Mechanical reliability — proven technology with decades of field service
- Legal record — paper chart serves as tamper-proof documentation
Installation Requirements:
- Mount on flat vertical surface using M4 screws (2 points) or DIN rail (if adapter available)
- Ensure adequate ventilation — minimum 50 mm clearance on top and sides
- Connect field signals to rear terminal block — observe correct polarity
- Set chart paper speed and pen zero before operation
- Configure alarm setpoints using front panel knobs
Usage Precautions:
- Replace ink pen cartridges regularly (typically every 6–12 months depending on usage)
- Use only Yokogawa Type 2SA chart paper — other sizes will not feed correctly
- Do not operate in environments exceeding +50°C or below 0°C
- Clean pen tip with approved solvent if recording becomes faint
- Backup critical data digitally — paper charts degrade over time