The TM21001045-2SN is a 45-point wiring terminal block module designed for the CENTUM VP and CS3000 DCS I/O stations. It provides organized, secure connection points for field instrument wiring to I/O cards. The “2SN” suffix indicates the terminal block type with screw-clamp connection for reliable wire termination.

Detailed content

Technical Specifications:

  • Model Code: TM21001045-2SN
  • Number of Terminal Points: 45 points
  • Terminal Type: Screw-clamp (captive screw, spring-loaded)
  • Wire Gauge Compatibility: 0.5 mm² to 2.5 mm² (AWG 20 to AWG 14)
  • Rated Voltage: 250 VAC / 30 VDC
  • Rated Current: 10 A per terminal
  • Contact Material: Phosphor bronze with tin plating
  • Insulation Resistance: ≥ 100 MΩ (at 500 VDC)
  • Dielectric Strength: 1500 VAC (1 minute, terminal to terminal)
  • Operating Temperature Range: 0°C to +55°C
  • Storage Temperature Range: -20°C to +70°C
  • Relative Humidity: 5% to 95% RH (non-condensing)
  • Material Composition:
    • Housing: Polycarbonate (PC) + Glass Fiber (GF30%) — UL94 V-0 rated
    • Terminal: Phosphor bronze, tin-plated
    • Screw: Stainless steel (SUS304)
  • Dimensions (W × H × D): 100 mm × 90 mm × 80 mm (approx.)
  • Weight: Approximately 350 g
  • Mounting Method: DIN rail (35 mm) mounting or panel mounting

Functional Features:

  • Provides 45 individual connection points for field wiring
  • Color-coded terminal rows for organized wiring (power, input, output)
  • Marking strips for wire labeling (supplied with module)
  • Pre-wired jumper connections available for common signal routing
  • Compatible with all F3-series I/O cards (AI, AO, DI, DO, TC, RTD)

Structural Features:

  • Modular design with snap-on cover for wire protection
  • Hinged front cover for easy wire access during maintenance
  • Grounding bus bar integrated for chassis earth connection
  • Cable entry points on top and bottom

Applicable Industries:
All industries utilizing CENTUM VP / CS3000 DCS: Oil & Gas, Petrochemical, Power, Water Treatment, Chemical, Pharmaceutical, Paper

Installation Requirements:

  • Mount on 35 mm DIN rail inside I/O cabinet
  • Use ferrule-terminated wire ends for AWG 22 and smaller
  • Tighten screws to torque of 0.5 N·m (do not over-tighten)
  • Maintain wire bend radius ≥ 30 mm at terminal exit

Precautions:

  • Do not use wire gauge > 2.5 mm² (AWG 14) — will damage terminal
  • Do not use wire gauge < 0.5 mm² (AWG 20) — poor contact reliability
  • Ensure stripped wire length is 8 mm to 10 mm for optimal contact
  • Do not connect different voltage levels on adjacent terminals without isolation