  • Product Name: High‑Performance Paperless Recorder Module
  • Model Series: GX Series Paperless Recorders
  • Technical Specifications: Input channels: expandable multi‑channel universal input; display: color LCD touchscreen; sampling rate: up to 100 ms per channel; storage capacity: internal flash memory + external SD card support; communication ports: Ethernet, RS‑485, USB; operating temperature: 0 °C to +50 °C; IP54 front‑panel protection

Detailed content

  • Functional Features: Real‑time data recording, trend display and analysis; alarm monitoring & event logging; mathematical calculation functions; batch data management; remote data access via network; report generation; high‑speed data acquisition
  • Performance Parameters: Measurement accuracy: ±0.02% FS for voltage/current inputs; data retention: permanent storage for recorded data; sampling precision: 24‑bit A/D conversion; data upload speed compliant with Modbus‑TCP/IP protocol
  • Material Composition: Aluminum alloy front panel; industrial‑grade plastic housing; high‑resolution touch LCD screen; anti‑vibration internal structural components
  • Structural Characteristics: Panel‑mount design for control rooms; modular input terminal units; integrated communication interface modules; compact wall/panel installation structure
  • Working Principle: Collects multi‑type process signals (temperature, pressure, flow, voltage, current); converts analog signals to digital data; stores data in non‑volatile memory; visualizes data trends and alarms via human‑machine interface (HMI)
  • Advantages: High‑precision multi‑parameter recording; network‑enabled remote monitoring; large‑capacity data storage; user‑friendly touch operation; robust environmental adaptability; comprehensive data analysis tools
  • Applicable Industries: Pharmaceutical manufacturing, food processing, energy, water supply, environmental monitoring, chemical industry, building automation
  • Installation Requirements: Panel cutout mounting (standard industrial panel size); horizontal installation only; maintain proper ventilation around the unit; connect dedicated power supply with stable voltage
  • Usage Precautions: Avoid direct sunlight on the touchscreen; prevent dust and moisture ingress into the housing; use authorized SD cards for data backup; calibrate input channels periodically per Yokogawa calibration standards