Digital guide

You are here:

Kollmorgen LE06555

Product Overview:
The LE06555 is a glass scale linear encoder system from Kollmorgen. “LE” = Linear Encoder. “06555” encodes the specific model: 06 = 6μm signal period (166.7 lines/mm), 55 = 55mm read head width, 5 = 5m scale length (or similar variant coding). This is a high-precision external linear position feedback device.

Detailed content

Key Technical Specifications:

Parameter Value
Type Glass Scale Linear Encoder (incremental, with reference mark)
Signal Period 6 μm (166.7 lines/mm)
Resolution (with interpolation) Up to 5 nm (with 100× interpolation)
Scale Length 500mm – 5000mm (variant dependent, 06555 typically = 550mm or 5000mm)
Read Head Width 55mm
Accuracy (±) ±1.5 μm (over full scale)
Repeatability (±) ±0.5 μm
Output Signals A, B, Z (TTL/RS-422), optional Sin/Cos (1Vpp)
Operating Voltage 5VDC (logic), 5VDC (excitation for Sin/Cos)
Operating Temperature 0°C to +60°C (scale), -20°C to +80°C (read head)
Scale Material Glass (low CTE: 0.5 ppm/°C)
Read Head Material Aluminum housing, stainless steel flexure
Enclosure Rating (Read Head) IP65 / IP67
Cable Length (max) 10m (standard), 20m (with line driver)
Mounting Adhesive tape or screw mounting (scale), bracket mounting (read head)
Weight (Read Head) 0.08 kg
Weight (Scale, per meter) 0.03 kg/m

Working Principle:
A light source (LED) shines through a glass scale with precisely etched lines. The read head detects the light/dark pattern and generates quadrature signals (A/B) for position counting. The Z signal provides a single reference mark per scale length.

Advantages:

  • Glass scale has near-zero thermal expansion — critical for long-travel precision
  • Nanometer-level resolution with interpolation
  • No wear — infinite lifetime (no mechanical contact)
  • Immune to contamination (IP65/IP67 read head)

Applicable Industries:
CNC machine tools (linear axis feedback), coordinate measuring machines (CMM), lithography stages, semiconductor wafer steppers, large-format 3D printers, precision gantries.

Installation Requirements:

  • Scale must be mounted on a flat surface with flatness < 0.02mm over full length
  • Read head must be mounted with 0.05mm parallelism to scale surface
  • Air gap between scale and read head: 0.5mm ± 0.1mm
  • Avoid mounting near heat sources (scale CTE is low but not zero)
  • Use shielded cable, ground at controller end only

You may also like