Detailed content
Free Air Delivery (FAD): 12.0 m³/min (12000 L/min) at 7 bar
Working Pressure: 7 bar (101 psi) — standard; adjustable up to 13 bar
Drive Type: Diesel Engine (Kubota/Perkins or equivalent) — Direct-Coupled
Cooling Method: Air-Cooled / Water-Cooled (engine) + Air-Cooled (airend)
Oil Classification: Oil-Injected (ISO 8573-1 Class 1 with filtration)
ISO Purity Class: Class 1
Controller: Elektronikon Controller with Basic/Touch Interface
Networking Capability: Standard — basic monitoring available
Mobility: 4-wheel towable trailer with road lights and braking system
Dimensions (L×W×H): 4200 × 1800 × 2100 mm (approximate, trailer-mounted)
Weight: ~3200 kg (operating weight)
Fuel Tank Capacity: ~300 liters
Structure Features:
- Heavy-duty galvanized steel trailer chassis
- Diesel engine with electric start
- Rotary screw airend with belt or direct drive
- Plate-fin aftercooler
- Coalescing oil separator
- Sound-attenuated canopy (optional)
- ROPS/FOPS rated operator enclosure
Working Principle:
Diesel engine drives rotary screw airend producing compressed air at 12 m³/min. Air is compressed, cooled via aftercooler, separated from oil via coalescing filter, and delivered at 7 bar. The unit is fully self-contained — no external power required for operation (electric start uses battery).
Key Features:
- Fully mobile — towable on public roads with trailer license
- No external power needed — diesel-driven, self-contained
- High output: 12 m³/min — suitable for multiple simultaneous users
- Robust construction — built for construction sites, mining, remote locations
- Quick setup — connect air hose and start
Advantages:
- Complete independence from grid power
- High capacity for demanding field applications
- Low total cost of ownership for temporary/remote use
- Rugged design for harsh environments
Applicable Industries:
- Construction Sites
- Mining Operations
- Road & Infrastructure Projects
- Event & Entertainment (temporary air supply)
- Emergency & Disaster Relief
- Sandblasting & Surface Preparation
- Drilling Operations
Installation Requirements:
- Level ground surface for stable operation
- No indoor installation required — designed for outdoor use
- Ambient: -20°C to +45°C (with cold-start package)
- Fuel: Diesel (EN 590 compliant)
- Exhaust routing: ensure adequate clearance from structures
- Air hose connection: DN50 or DN65 coupling
Usage Precautions:
- Never operate in enclosed spaces without exhaust ventilation — CO hazard
- Daily check: engine oil level, coolant level, fuel level
- Service interval: every 500 hours or 6 months (whichever first)
- Air filter: every 500 hours
- Oil filter: every 500 hours
- Oil separator: every 2000 hours
- Store in dry conditions — drain all water from tank before long-term storage