Digital guide

You are here:

YOKOGAWA UP55A-000-110

Manufacturer: Yokogawa Electric Corporation

Product Introduction:
The UP55A-000-110 is a 6-channel universal input paperless recorder from Yokogawa’s UP55A series. It is a 1/8 DIN (96 × 48 mm) panel-mount recorder designed for multi-channel data acquisition, display, recording, and alarm monitoring in industrial process environments. The “000” denotes 6 universal input channels, and “110” denotes 100–240 V AC power supply.

Detailed content

Measurement Principle:
The recorder uses high-speed A/D converters (24-bit) to digitize analog input signals from thermocouples, RTDs, DC voltage, DC current, and frequency sensors. Data is processed, displayed in real-time on the LCD, stored in internal NAND flash memory, and can be transmitted via RS-232C, RS-485, or Ethernet (Modbus TCP) to a host system.

Technical Specifications:

Parameter Specification
Model UP55A-000-110
Number of Channels 6 Universal Input Channels (000 = 6 ch)
Input Types TC (J, K, T, E, R, S, B, N, W), RTD (Pt100, Pt1000, Cu50, JPt100), DC V (0–100 mV, 0–1 V, 0–5 V, 0–10 V), DC mA (0–20 mA, 4–20 mA), Frequency (0–1 kHz)
Display 128 × 64 pixel Monochrome LCD with White LED Backlight
Recording Interval 0.1 sec to 3600 sec (selectable)
Recording Memory 64 MB internal flash (approx. 20 days at 1 sec interval for 6 ch)
Accuracy (DC V) ±0.1% of F.S. ±1 digit
Accuracy (DC mA) ±0.1% of F.S. ±1 digit
Accuracy (TC/RTD) ±0.1% of reading or ±1°C (whichever is greater)
Power Supply 100–240 V AC, 50/60 Hz (110)
Communication RS-232C, RS-485 (Modbus RTU), Ethernet (Modbus TCP/EtherNet/IP)
Alarm Outputs 4 Relay Outputs (alarm, batch, etc.)
Analog Output 1 Channel (4–20 mA DC, selectable)
Protection Class NEMA 4 / IP66 (front panel)
Dimensions 96 × 48 × 118 mm (W × H × D)
Cutout Size 92 × 44 mm (1/8 DIN)
Weight Approx. 0.4 kg
Approvals CE, UL, CSA, FM (for hazardous areas — check specific variant)

Structural Features:

  • 1/8 DIN (96 × 48 mm) panel-mount form factor — extremely space-efficient
  • Monochrome LCD with high visibility in all lighting conditions
  • Front panel keypad with membrane keys for local operation
  • SD card slot (optional) for data backup and transfer
  • 4 relay alarm outputs with programmable setpoints
  • Compact depth (118 mm) — fits in shallow panels

Performance Parameters:

Parameter Value
Sampling Rate 200 ms per channel (6 ch), 100 ms per channel (3 ch)
Data Retention 10 years (with SD card backup)
Number of Recordings Up to 100 recording files
Batch Recording Yes — up to 100 batches
Event Recording Yes — captures alarm events with timestamp
Remote Display Yes — via Web browser (Ethernet models)
Power Consumption ≤ 8 VA
Operating Temperature 0°C to +50°C (32°F to +122°F)
Storage Temperature -20°C to +60°C (-4°F to +140°F)

Key Advantages:

  • 6 universal input channels in 1/8 DIN size — highest channel density in its class
  • Supports ALL major sensor types — TC, RTD, mA, V, frequency — no need for multiple recorders
  • Ethernet connectivity — remote monitoring via web browser without additional software
  • NAND flash memory — no moving parts, no paper, no ink
  • SD card backup — easy data archival and transfer
  • Batch recording function — ideal for batch process industries

Applicable Industries:

  • Chemical and Petrochemical Processing
  • Pharmaceutical Manufacturing
  • Food and Beverage (Batch Processes)
  • Power Generation
  • HVAC and Building Automation
  • Environmental Monitoring
  • Laboratory and R&D

Installation Requirements:

  • Cut panel opening to 92 × 44 mm for 1/8 DIN mounting
  • Secure with mounting clips or screws (provided)
  • Connect all input signals using appropriate thermocouple extension wire or shielded cable
  • For RS-485 communication: use shielded twisted-pair cable; terminate with 120 Ω resistor at the last device
  • For Ethernet: use Cat5e or higher cable; connect to a managed switch for best performance
  • Ground the recorder chassis to the panel ground bus

Usage Precautions:

  • Do not exceed the rated input voltage/current for any channel — this will damage the A/D converter
  • Use correct thermocouple type settings — mismatched type settings cause large errors
  • Perform cold junction compensation (CJC) verification periodically
  • Back up data to SD card before firmware updates
  • Do not block the ventilation slots on the top and bottom of the unit
  • Do not apply power with incorrect voltage — 110 = 100–240 V AC only
  • Replace the internal backup battery (if equipped) every 2 years to preserve clock and settings