  • Product Series: UM Series Universal Transmitter / Process Signal Conditioner
  • Product Name: UM1L Series Isolated Signal Transmitter
  • Product Brief: A compact, DIN‑rail mounted industrial signal isolation and conversion device manufactured by Yokogawa, designed for reliable transmission, isolation, and conditioning of analog process signals in industrial automation control systems.

Detailed content

  • Technical Specifications:
    • Model code: UM1L‑130E‑1A2SA‑2/oE
    • Input signal: Standard industrial analog inputs including 4–20 mA DC, 0–10 V DC
    • Output signal: Isolated 4–20 mA DC analog output
    • Power supply: 24 V DC nominal operating voltage
    • Isolation type: Galvanic isolation between input, output, and power circuits
    • Mounting standard: DIN rail 35 mm standard mounting
  • Functional Features: Signal isolation, noise suppression, analog signal conversion, surge protection, loop‑powered operation compatibility
  • Performance Parameters:
    • Accuracy: ±0.1% of full scale
    • Response time: ≤200 ms
    • Operating temperature range: −20 °C to +60 °C
    • Insulation resistance: ≥100 MΩ at 500 V DC
  • Material Composition: Flame‑retardant ABS plastic housing, copper alloy terminal connectors, printed circuit board with industrial‑grade electronic components
  • Structural Features: Slim‑body compact design, screw‑type terminal connections, modular single‑unit structure
  • Working Principle: Receives analog process signals, performs galvanic isolation and linear conversion via internal isolation amplifiers and signal processing circuits, outputs standardized isolated signals for control system acquisition
  • Advantages: High‑precision signal transmission, strong anti‑interference capability, compact footprint, easy installation and maintenance, long‑term operational stability
  • Applicable Industries: Petrochemical, power generation, water treatment, pharmaceutical manufacturing, pulp and paper, general process industry automation
  • Installation Requirements: DIN‑rail mounting, well‑ventilated cabinet environment, wiring separation for power and signal lines, compliance with industrial electrical safety standards