Yokogawa UD1045B0KC-2XN
Working Principle: The UD1045B0KC-2XN acquires analog and digital input signals from field instruments, converts them via high-speed A/D converters (16-bit resolution), and displays/records the data on a color TFT LCD screen. Data is stored in internal flash memory (up to 8 GB) and can be exported via USB, Ethernet, or RS-232C. The recorder supports real-time trend display, bar graph, numerical display, and alarm monitoring.
Detailed content
Model Breakdown:
| Code | Meaning |
|---|---|
| UD1000 | Paperless Recorder Series |
| 45 | 45 Input Channels (Maximum) |
| B0KC | Configuration Code: B0 = Universal Input; K = Alarm/Event Function; C = Specific communication option |
| 2XN | 2 = Dual recording mode; X = Extended function; N = No special option |
Technical Specifications:
| Parameter | Specification |
|---|---|
| Number of Channels | 45 Channels (Maximum) |
| Display | 8.4-inch Color TFT LCD (640 × 480 pixels, 65,536 colors) |
| Input Types | DC Voltage: 1–5 V, DC Current: 4–20 mA, TC: J, K, T, E, R, S, B, N; RTD: Pt100, JPt100, Pt1000; Frequency, Pulse, Contact (DI) |
| A/D Resolution | 16-bit |
| Scan Cycle | 0.2 seconds (all 45 channels) |
| Recording Interval | 0.1 second to 60 minutes (adjustable per channel) |
| Memory Capacity | 8 GB Internal Flash Memory (approx. 500 days at 1-second interval for 45 channels) |
| Alarm Output | 4 Alarm Outputs (SPDT Relay), 250V AC / 2A |
| Event Input | 8 Digital Event Inputs (for sequence-of-events recording) |
| Communication Ports | Ethernet (10/100 BASE-T), RS-232C, USB 2.0 (Host & Device) |
| Protocols | Modbus RTU, Modbus TCP, HTTP, FTP, SMTP (email) |
| Power Supply | 100–240 V AC, 50/60 Hz (Universal input) |
| Power Consumption | Maximum 35 VA |
| Operating Temperature | 0°C to +50°C (32°F to +122°F) |
| Operating Humidity | 20% to 85% RH (non-condensing) |
| Front Panel Protection | IP65 / NEMA 4 (Dust and water splash proof) |
| Dimensions (W×H×D) | 250 × 200 × 180 mm (9.8 × 7.9 × 7.1 inches) |
| Weight | Approximately 3.0 kg (6.6 lbs) |
| Certification | CE, UL, CSA, FCC, ATEX (hazardous area variants available) |
Material Composition:
- Front Bezel: Flame-retardant Polycarbonate (Smoke Gray)
- Housing: Aluminum Die-Cast with Powder Coat Finish
- Display Cover: Scratch-resistant Polycarbonate with anti-glare coating
- Terminal Block: Screw-type, 1.5 mm² to 2.5 mm² wire size
- Internal PCB: FR-4 Glass Epoxy, conformal coated
Structural Features:
- Panel-mount design (96 × 96 mm cutout)
- 8.4-inch wide color display — supports multi-window layout (trend + bar graph + numerical simultaneously)
- USB port on front panel — direct data export to flash drive
- Ethernet port — remote access via web browser
- Alarm annunciation LED on front panel
- Internal clock with battery backup — maintains time stamp during power loss
Applicable Industries:
- Oil & Gas (Upstream, Midstream, Downstream)
- Chemical & Petrochemical
- Power Generation (Thermal, Nuclear, Hydro, Renewable)
- Water & Wastewater
- Pharmaceutical
- Food & Beverage
- Steel & Metals
- Pulp & Paper
Advantages & Highlights:
- 45-channel capacity — consolidates multiple recorder functions into one unit
- 8.4-inch color display — superior visibility vs. monochrome recorders
- 8 GB internal memory — eliminates need for external storage in most applications
- Ethernet + USB + RS-232C — flexible data export and remote monitoring
- Multi-window display — trend, bar graph, and numeric values simultaneously
- HART input support — can accept HART field devices directly
- Event recording — captures sequence-of-events for troubleshooting
Installation Requirements:
- Cut 96 × 96 mm panel opening for flush mounting
- Use shielded twisted-pair cable for analog inputs (TC/RTD)
- Connect Ethernet cable (CAT5e or higher) for remote access
- Verify power supply voltage matches nameplate rating (100–240 V AC)
- Ground the recorder chassis to plant earth ground
- Configure channel assignments and alarm setpoints via front panel or PC software (UTAdvanced Logger) before commissioning
Usage Precautions:
- Do not exceed 45 input channels — each channel consumes scan cycle time
- Backup data regularly via USB or Ethernet — internal memory is not infinite
- Do not expose to direct sunlight — display degradation may occur above +50°C
- Clean front panel with soft dry cloth — do not use solvents on display
- Update firmware periodically via Yokogawa UTAdvanced Logger software
- Use surge protector on power line to protect against voltage spikes