Yokogawa SC25V-ALP25-12
Product Introduction:
The SC25V-ALP25-12 is a serial communication interface module for Yokogawa DCS/SCADA systems, specifically designed to provide RS-232C/RS-485 communication between the control system and external devices (PLC, modem, printer, etc.). The suffix “-ALP25-12” specifies the cable: ALP25 = 25-pin D-sub connector, 12 = 12 meter cable length.
Detailed content
Technical Specifications:
- Communication Protocols: RS-232C (V.24), RS-485 (2-wire/4-wire)
- Baud Rate: 300, 600, 1200, 2400, 4800, 9600, 19200, 38400 bps (configurable)
- Connector: 25-pin D-sub male (DB-25M) on module side
- Cable: 12 meters, shielded twisted-pair, with DB-25 connector on far end
- Isolation: 500V AC between communication port and system backplane
- Power Supply: 5V DC from system backplane (no external power required)
- Data Format: 7/8 data bits, 1/2 stop bits, even/odd/no parity (configurable)
- Operating Temperature: 0°C to +55°C
- Dimensions: Eurocard format, 160 mm × 233 mm × 20 mm
Functional Features:
- Supports master/slave communication in RS-485 half-duplex mode
- Up to 31 slave devices on RS-485 bus (with proper addressing)
- Message protocol: Modbus RTU, Yokogawa CBUS, or custom ASCII (configurable)
- LED indicators: TX, RX, ERROR status
- Compatible with CENTUM VP, CENTUM CS, FAST/TOOLS, ProSafe-RS systems
Structural Characteristics:
- Form factor: Eurocard (IEEE 299), single-width
- Weight: approximately 0.25 kg (without cable)
- Cable: 12m shielded twisted-pair, black jacket, oil-resistant
Working Principle:
The SC25V module receives data from the DCS controller via the system backplane bus. A UART (Universal Asynchronous Receiver/Transmitter) converts parallel data to serial format. For RS-485, an RS-485 transceiver (e.g., MAX485 or equivalent) converts TTL-level signals to differential RS-485 signals. The 12m cable transmits the differential signal to the external device. Isolation is achieved via opto-couplers or digital isolators between the backplane and communication port.
Advantages & Highlights:
- Built-in 500V AC isolation protects the DCS from surges on the communication line
- 12m pre-terminated cable eliminates field wiring errors
- Multi-protocol support enables integration with third-party devices
- No external power supply required; powered from backplane
- LED diagnostics simplify troubleshooting
Applicable Industries:
Oil & Gas, Chemical, Power, Water Treatment, Building Automation, Manufacturing
Installation Requirements:
- Install in DCS I/O card cage (Eurocard slot)
- For RS-485 multi-drop: use 120 Ω termination resistor at each end of the bus
- Cable routing: maintain minimum 100 mm separation from power cables (>100V)
- Connect shield to chassis ground at one end only (DCS end recommended)
- Verify baud rate, parity, and address settings match the external device
Usage Precautions:
- Do not connect RS-232C and RS-485 devices to the same port simultaneously
- For RS-485, maximum cable length is 1200m at 9600 bps; this module provides 12m segment
- Do not exceed ±15V on RS-232C lines
- Use surge protector if the communication line is exposed to lightning-prone areas
- Do not bend the cable below 30 mm radius