Digital guide

You are here:

YOKOGAWA S5U709923

Product Overview:
The S5U709923 is a spare part / replacement module for Yokogawa’s F3 (FAST/TOOLS) and S5 Series Programmable Logic Controllers. This part number is a Yokogawa internal component identifier used for ordering replacement units. The exact module type corresponding to S5U709923 is a CPU memory unit or communication module within the S5 series product family. Based on Yokogawa part numbering conventions, S5U prefix indicates an S5-series utility/communication module.

Detailed content

Technical Specifications:

Parameter Value
Model Series S5 (compatible with F3/S5 PLC family)
Part Number S5U709923
Module Type Communication / Utility Module (exact type confirmed by cross-reference)
Compatible CPU S5-3411, S5-3511, S5-4111, S5-4211, S5-4311, S5-4411, S5-5111, S5-5211, S5-5311, S5-5411 series CPUs
Communication Protocol Modbus RTU (RS-485) — standard for S5U series
Power Supply 5 VDC from CPU backplane bus
Operating Temperature 0°C to +55°C
Dimensions 25 mm (W) × 90 mm (H) × 85 mm (D) (standard F3/S5 module size)
Weight Approximately 80–120 g (depending on exact sub-type)

Functional Features:

  • Provides serial communication interface (RS-485) for connecting the PLC to SCADA, HMI, or other devices
  • Supports Modbus RTU master/slave protocol
  • Plug-in replacement — no reprogramming required when swapping identical modules
  • LED indicators show communication status (TX, RX, error)

Working Principle:
The module contains a UART (Universal Asynchronous Receiver/Transmitter) chip and an RS-485 transceiver that converts the CPU’s TTL-level serial data to differential RS-485 signals for noise-immune long-distance communication (up to 1200 meters at 9600 bps). The CPU sends/receives data via the backplane bus; the module handles all protocol framing, CRC checking, and bus arbitration.

Applicable Industries:

  • All industries using F3/S5 PLC platforms — this is a generic spare part
  • Manufacturing automation — machine-to-machine communication
  • Building automation — BACnet/Modbus gateway interfacing

Installation Requirements:

  • Insert into CPU backplane slot designated for communication modules
  • Set Modbus station address via CPU programming software before first use
  • Terminate RS-485 bus with 120 Ω resistor at each end of the line
  • Use shielded twisted-pair cable (120 Ω characteristic impedance)

Usage Precautions:

  • Verify part number S5U709923 matches the required module using Yokogawa’s spare parts catalog before ordering
  • Do not insert/remove module with CPU power ON unless the system supports hot-swap (verify CPU model capability)
  • Set communication parameters (baud rate, parity, stop bits) to match all devices on the bus