Digital guide

You are here:

Yokogawa MX110-V4R-M06

Product Series: MX100/MX110 Series — Yokogawa Paperless Recorders

Product Overview:
The MX110-V4R-M06 is a single-channel (1-ch) paperless recorder featuring a 4.3-inch color VGA display (V4R) and 64 MB memory (M06). This device replaces traditional chart recorders by digitally recording process data (temperature, pressure, flow, voltage, etc.) with timestamped data logging and alarm management capabilities.

Detailed content

Technical Specifications:

Parameter Specification
Number of Channels 1 channel (universal input)
Display 4.3-inch color TFT VGA (640 × 480 pixels) (V4R)
Memory Capacity 64 MB (M06) — approximately 12 million data points
Input Types TC (J, K, T, E, R, S, B, N), RTD (Pt100, JPt100, Pt1000, Ni100, Cu50), DC mA (0-50mA), DC V (0-100mV to 5V), Frequency (0-1kHz)
Sampling Rate 100 ms (standard), 50 ms (fast mode)
Recording Interval 1 second to 60 minutes (configurable)
Accuracy ±0.1% of reading ±1 digit (DC input), ±0.2% of span (TC/RTD)
Alarm Functions 4 alarm outputs (relay contacts), 4 alarm setpoints per channel
Communication RS-232C, USB (front panel), Ethernet (optional module)
Power Supply 100-240 VAC, 50/60 Hz or 24 VDC
Operating Temperature 0°C to +50°C (+32°F to +122°F)
Dimensions (W×H×D) 96 × 96 × 132 mm (DIN 96×96 mm cutout)
Weight Approximately 0.6 kg
Certifications UL, CSA, CE, FCC Class A

Functional Features:

  • Color trend display with up to 8 pen colors for multi-variable monitoring
  • USB data export — CSV format for easy spreadsheet import
  • Password-protected parameter settings (3 access levels)
  • Event marker function — manually tag significant process events
  • Scaling and engineering unit conversion built-in
  • Recorder paper emulation display mode for operator familiarity

Material Composition:

  • Front panel: ABS resin, flame-retardant UL94 V-0
  • HousingAluminum die-cast with epoxy powder coating
  • Display coverPolycarbonate, anti-glare coating

Applicable Industries:

  • Pharmaceutical — Batch process recording and validation
  • Food & Beverage — Temperature monitoring for HACCP compliance
  • Chemical Plants — Continuous process trend logging
  • Water Treatment — Flow and level recording
  • Facility Management — Energy consumption monitoring

Installation Requirements:

  • DIN 96×96 mm panel cutout required for front-mount installation
  • Mount with minimum 50 mm clearance above for ventilation
  • Power supply voltage must match unit rating (100-240VAC or 24VDC)
  • Ground terminal must be connected to building earth
  • Input wiring: Use shielded cable for TC/RTD inputs

Usage Precautions:

  • Do not exceed input voltage limits: TC: ±50mV, RTD: 3.5V max excitation
  • Replace internal battery every 5 years to preserve memory during power loss
  • Export data regularly — memory is not infinite (64 MB ≈ 12M points)
  • Clean display with soft cloth only — no solvents or abrasives
  • Calibrate annually using certified reference standards