Digital guide

You are here:

Yokogawa MW100-E-1W

Product Series: MW100 Series — Yokogawa Paperless Recorders

Product Overview:
The MW100-E-1W is a single-width (1W), 1-channel paperless recorder from the Yokogawa MW100 series with built-in Ethernet communication (E). This compact recorder provides high-accuracy process data recording with network connectivity for remote monitoring and data archival.

Detailed content

Technical Specifications:

Parameter Specification
Number of Channels 1 channel (1W = single-width)
Display Monochrome LCD (128 × 64 dots) with LED backlight
Communication Ethernet 10/100BASE-TX (E)
Memory Capacity 2 MB internal flash (approximately 300,000 data points)
Input Types DC mA (4-20mA, 0-20mA), DC V (0-5V, 1-5V, 0-10V), TC (K, J, T, E, R, S, B, N), RTD (Pt100, JPt100)
Sampling Rate 200 ms (standard)
Accuracy ±0.2% of span (DC input), ±0.3% of reading (TC/RTD)
Alarm Outputs 2 relay alarm outputs (SPDT, 250VAC/3A or 30VDC/3A)
Power Supply 100-240 VAC, 50/60 Hz or 24 VDC
Operating Temperature 0°C to +50°C (+32°F to +122°F)
Dimensions (W×H×D) 48 × 96 × 112 mm (DIN 48×96 mm cutout — half-DIN width)
Weight Approximately 0.35 kg
Certifications UL, CSA, CE, FCC Class A

Functional Features:

  • Ethernet connectivity enables remote access via web browser (HTTP)
  • FTP client function — automatic data upload to server at configured intervals
  • Email alarm notification with snapshot attachment
  • Compact half-DIN width — fits in space-constrained panels
  • Universal input — auto-detects input type (TC, RTD, mA, V)
  • Recording interval: 0.5 sec to 60 min

Structure Characteristics:

  • Half-DIN (48×96 mm) form factor — space-saving design
  • Snap-in DIN rail mounting with rear clip
  • Screw terminal blocks for field wiring (no tools required for wiring)
  • LED indicators: Power (green), Alarm (red), Communication (amber)

Applicable Industries:

  • HVAC Systems — Duct temperature and damper position recording
  • Small-scale Manufacturing — Single-point process monitoring
  • Building Automation — Energy metering and trending
  • Pump Stations — Pressure and flow recording
  • Environmental Monitoring — Temperature and humidity logging

Installation Requirements:

  • DIN 48×96 mm panel cutout for front-mount installation
  • Ethernet cable: Cat5e or higher, max 100 m to network switch
  • Power supply: 100-240VAC or 24VDC (verify rating on nameplate)
  • Ground connection mandatory — use dedicated grounding terminal

Usage Precautions:

  • Ethernet IP address must be unique on the network — avoid conflicts
  • Maximum recording interval: 60 minutes for 2 MB memory longevity
  • Do not connect inputs exceeding specified ranges — risk of permanent damage
  • Firmware updates available via Ethernet — check Yokogawa website regularly
  • Back up recorded data before firmware updates