Digital guide

You are here:

YOKOGAWA MW100-E-1H

Product Introduction:
The MW100-E-1H is a high-precision weight transmitter from Yokogawa’s MW100 product line. The “E” designation indicates the enhanced functionality variant, and “1H” specifies the particular output and configuration code. This transmitter converts the low-level millivolt signal from load cells into a standardized 4–20 mA output with HART digital communication capability.

Detailed content

Technical Specifications:

  • Input Signal: 0.5 to 3 mV/V (load cell mV output)
  • Output Signal4 to 20 mA DC (2-wire), HART 7 protocol
  • Excitation Voltage: 10 V DC (regulated, 50 mA max)
  • Accuracy: ±0.02% of calibrated span
  • Temperature Drift: ±0.002% of span per °C (0 to 50°C)
  • Response Time: ≤10 ms (10% to 90% step change)
  • Operating Temperature: -20°C to +70°C
  • Protection RatingIP65 / NEMA 4X (front panel)
  • Power Supply12 to 36 V DC (loop-powered)

Functional Features:

  • Supports HART 7 digital communication for remote configuration and diagnostics
  • Zero and span calibration via HART communicator or local push buttons
  • Built-in digital filtering with selectable time constants (0.2 s to 10 s)
  • Overload protection rated at 150% of full scale
  • Reverse polarity protection on power supply input

Performance Parameters:

Parameter Value
Load Cell Input Impedance 350 Ω to 1000 Ω
Insulation Resistance ≥100 MΩ at 500 V DC
Dielectric Strength 1500 V AC for 1 minute (input to output to chassis)
Loop Resistance (max) 600 Ω at 24 V DC supply

Material Composition:

  • HousingAluminum die-cast with epoxy powder coating (RAL 7032 pebble gray)
  • Terminal BlockPhosphor bronze with tin plating
  • Seals: Fluorocarbon rubber (Viton) gaskets

Structural Characteristics:

  • Dimensions: 96 mm (W) × 144 mm (H) × 112 mm (D)
  • Weight: Approximately 1.4 kg
  • Mounting: Wall-mount or pipe-mount (35 mm DIN rail compatible via adapter)
  • Display: 4-digit LCD with backlight (shows mA output, error codes)

Working Principle:
The MW100-E-1H receives the millivolt/volt signal from a load cell, amplifies it using a precision instrumentation amplifier with auto-zero calibration, converts it to a 4–20 mA current loop output via a 16-bit D/A converter, and superimposes HART FSK (Frequency Shift Keying) digital signals on the same loop for bidirectional communication.

Key Advantages:

  • ±0.02% accuracy — among the highest in the weight transmitter class
  • HART 7 compatibility enables remote diagnostics without physical access
  • IP65 front panel allows deployment in washdown and outdoor environments
  • Compact form factor reduces panel space requirements

Applicable Industries:

  • Pharmaceutical batch weighing
  • Food and beverage production line weighing
  • Chemical process batch control
  • Bulk material hopper and silo weighing
  • Packaging and filling machines

Installation Requirements:

  • Mount at ambient temperature within -20°C to +70°C
  • Route load cell cables in shielded twisted-pair, minimum 0.5 mm² cross-section
  • Connect shield ground at transmitter end only (single-point grounding)
  • Ensure loop power supply ≥12 V DC with adequate current headroom (≥25 mA)

Usage Precautions:

  • Do not exceed 36 V DC supply voltage — will destroy the internal regulator
  • Perform zero calibration with no load on the scale before each weighing session
  • Do not open the housing in explosive atmospheres — the unit is not intrinsically safe (purchase IS version if required)
  • Verify load cell mV/V rating matches transmitter input range (0.5–3 mV/V)