Yokogawa GX90XA‑06‑R1N‑3N
- Product Name: GX90XA‑06‑R1N‑3N 6‑Channel 4‑Wire RTD Analog Input Module
- Product Series: Yokogawa GX/GM Series Modular Data Acquisition I/O Module Series
- Product Brief: Specialized resistance temperature detector input module for high‑precision temperature measurement and data acquisition systems
Detailed content
- Technical Specifications:
- Channel Quantity: 6 independent measurement channels
- Input Type: 4‑wire RTD, 4‑wire resistance signal (solid‑state relay scanner type)
- Supported RTD Types: Pt100, JPt100, Cu10 series resistance thermometers
- Measurement Range: 0–2000 Ω resistance, -200°C ~ +850°C temperature
- Measurement Accuracy: ±0.05% FS (resistance), ±0.03°C (temperature)
- Sampling Speed: Min 100 ms per channel
- Isolation: Channel‑to‑channel electrical isolation
- Terminal Type: M3 screw terminal
- Operating Temperature: -10°C ~ +55°C
- Dimensions (W×H×D): 50 mm × 100 mm × 30 mm
- Weight: 0.22 kg
- Functional Features: High‑precision resistance measurement, self‑calibration function, signal anti‑interference filtering, hot‑swappable
- Performance Advantages: High stability for long‑term continuous measurement, compatible with GX10/GX20/GM10 data recorders
- Material Composition: Housing: Flame‑retardant plastic; Internal circuit: High‑precision A/D conversion chip, anti‑interference circuit board
- Structural Characteristics: DIN rail modular plug‑in design, compact size for dense installation
- Working Principle: Collect 4‑wire RTD resistance change signals, convert to temperature data via high‑precision A/D conversion and algorithm calculation
- Applicable Industries: Industrial temperature monitoring, pharmaceutical production, food processing, environmental testing, laboratory measurement systems
- Installation Requirements: Standard 35 mm DIN rail installation, avoid high‑temperature and high‑humidity environments
- Usage Precautions: Use 4‑wire shielded cables for signal wiring; regular calibration per measurement standards