Digital guide

You are here:

Yokogawa GC1000

Product Introduction: A high-performance online process gas chromatograph designed for continuous, real-time analysis of complex gas mixtures in industrial processes. It offers both isothermal and temperature-programmed models to meet diverse analytical requirements, providing precise component concentration measurement for process control and quality assurance.Technical Specifications
Models: GC1000 S/E/C (Isothermal); GC1000 D/T/W (Temperature-programmed)
Analysis Types: Multi-component gas analysis (hydrocarbons, permanent gases, etc.)

Detailed content

  • Detector Types: Flame Ionization Detector (FID), Thermal Conductivity Detector (TCD)
  • Sample Pressure: 0.02–0.5 MPa (gauge)
  • Sample Temperature: 0–150°C
  • Cycle Time: Typically 1–10 minutes (application-dependent)
  • Accuracy: ±0.5% of full scale (typical)
  • Communication: Integrates with Yokogawa CENTUM DCS via proprietary or standard protocols (Modbus, HART)
  • Power Supply: 100–240 V AC, 50/60 Hz
  • Operating Temperature: 5–40°C
  • Enclosure: IP54 (dust and water resistant)

    Key Features

  • Modular Design: Easy maintenance and component replacement (columns, detectors).
  • High Sensitivity: Detects trace components down to ppm levels.
  • Automatic Calibration: Built-in auto-calibration function for long-term stability.
  • Self-Diagnosis: Comprehensive fault detection and alarm system.
  • Seamless DCS Integration: Direct connectivity with Yokogawa CENTUM systems for closed-loop control.

    Applications

  • Oil refineries: Distillation column control, reformer monitoring, and product quality control.
  • Petrochemical plants: Olefin production, polymer feedstock analysis.
  • Natural gas processing: Pipeline quality monitoring, custody transfer measurement.
  • Chemical manufacturing: Process gas analysis for reaction control.
  • Environmental monitoring: Stack gas emission analysis.