  • Product Name: Yokogawa FP201 Series High‑Precision Miniature Pressure Sensor (Model FP201‑331‑L20A*B)
  • Product Introduction: Capacitive‑principle high‑precision pressure sensor for industrial high‑pressure process measurement, with built‑in signal amplification circuit and standard analog output.

Detailed content

  • Technical Specifications:
    • Measurement Principle: Capacitive Sensing
    • Pressure Range: 0‑350 kgf/cm²
    • Output Signal: 4‑20mA DC Standard Analog Signal
    • Basic Accuracy: ±0.25% FS
    • Temperature Drift: ±0.02% of span/°C
    • Protection Grade: IP66 Equivalent
    • Operating Temperature: ‑20°C ~ +80°C
    • Wetted Material: Hastelloy C Alloy
  • Function Features: Sealed diaphragm structure, high‑precision pressure detection, excellent temperature stability, standard 4‑20mA signal output compatible with all industrial control systemsYokogawa Electric Corporation.
  • Material Composition: 316L stainless steel housing, Hastelloy C pressure‑sensing diaphragm, copper alloy electrical terminals, high‑temperature‑resistant insulating materials.
  • Structural Features: Compact cylindrical miniature structure, integrated process pressure interface and electrical wiring interface, anti‑vibration sealed design.
  • Working Principle: Pressure changes deform the internal capacitive diaphragm, converting mechanical pressure changes into capacitance changes; the built‑in circuit converts capacitance signals into standard 4‑20mA electrical signals.
  • Advantage Highlights: Ultra‑high measurement precision, strong corrosion resistance, compact lightweight design, wide high‑pressure measurement range, long‑term zero‑point stability.
  • Applicable Industries: Hydraulic engineering, oil and gas exploration, high‑pressure chemical reaction vessels, mechanical pressure testing, process pipeline pressure monitoring.
  • Model Series: FP201 Series Miniature High‑Precision Pressure Sensors
  • Installation Requirements: Install vertically or horizontally on process pipelines/vessels; use standard thread connection; ensure pressure‑sensing diaphragm is fully exposed to measured medium; maintain vibration‑free installation position.
  • Usage Notes: Avoid pressure impact exceeding measurement range; clean pressure‑sensing diaphragm regularly for viscous‑medium applications; prohibit use in strong‑corrosion media incompatible with Hastelloy C.