Yokogawa FC311-S1 AS-S9391AT-02
Product Category: Field-Mounted Flow Rate Converter / Totalizer
Product Overview:
The FC311-S1 is a compact flow rate converter designed for field mounting. The configuration AS-S9391AT-02 specifies: S1 = Single-channel input, AS = Analog/Pulse input type, S9391AT = Specific I/O card assignment, 02 = Revision code. It processes flow sensor signals and outputs standardized 4–20 mA and pulse signals.
Detailed content
Technical Specifications:
- Input Signals: 4–20 mA DC, Pulse (contact closure), Frequency (0–10 kHz)
- Output Signals: 4–20 mA DC, Pulse output, Relay output (alarm)
- Power Supply: 24 VDC / 100–240 VAC (dual supply)
- Accuracy: ±0.1% of reading
- Display: 6-digit LED display (red, 14.2 mm digit height)
- Communication: RS-485 (Modbus RTU protocol)
- Pulse Input: Max 10 kHz, 5–24 VDC
- Relay Output: 250 VAC 3 A / 30 VDC 3 A (SPDT)
- Operating Temperature: -10°C to +55°C
- Protection Rating: IP65 (NEMA 4X front panel)
- Mounting: DIN rail / Wall mount / Pipe mount
- Dimensions: 96 mm × 96 mm × 110 mm (W × H × D)
Functional Features:
- Flow rate totalization (forward/reverse/net)
- Instantaneous flow rate display on 6-digit LED
- Analog output proportional to flow rate (4–20 mA)
- Pulse output for remote totalizer
- Relay alarm output (high/low flow alarm)
- Modbus RTU communication for DCS/SCADA integration
- Batch totalization with reset function
- Zero cut function (eliminates low-flow noise)
Material Composition:
- Housing: Die-cast aluminum alloy with powder-coat finish
- Front Panel: Polycarbonate with IP65 gasket seal
- Terminals: Phosphor bronze, tin-plated screw terminals
Structural Characteristics:
- Form Factor: Square 96×96 mm panel-mount housing
- Depth: 110 mm (behind panel)
- Weight: Approximately 700 g
Working Principle:
The FC311-S1 receives pulse, frequency, or 4–20 mA signals from a flow sensor (turbine, vortex, electromagnetic, etc.). The internal microprocessor calculates instantaneous flow rate and accumulated total using configurable K-factors and pipe dimensions. Results are output as 4–20 mA analog signal and pulse output, with alarm relay activation on setpoint violation.
Key Advantages:
- IP65 front panel — suitable for harsh field environments
- Multiple input types — compatible with virtually all flow sensors
- Built-in totalizer eliminates need for separate totalizer
- Modbus RTU enables seamless DCS integration
- Compact 96×96 mm size saves panel space
Applicable Industries:
- Oil & Gas (custody transfer, well monitoring)
- Chemical Processing
- Water & Wastewater
- Power Generation (cooling water, steam)
- Food & Beverage
Installation Requirements:
- Mount in location with ambient temperature -10°C to +55°C
- Use shielded cable for pulse input signals
- Provide 24 VDC or 100–240 VAC power supply
- For pipe mounting, use proper gasket and torque specifications
Usage Precautions:
- Do not exceed maximum input frequency of 10 kHz
- Verify K-factor and pipe size configuration matches actual sensor
- Ensure proper grounding of signal cables
- Do not disassemble in hazardous atmosphere