YOKOGAWA F3NC93-0N
Product Series: F3/F4 Series PLC Function Modules
Product Introduction:
The F3NC93-0N is a serial communication module for the Yokogawa F3/F4 series PLC systems. It provides RS-485 communication capability, enabling the PLC to function as a Modbus RTU master or slave device for integration with third-party equipment, HMIs, and SCADA systems.
Detailed content
Technical Specifications:
- Module Type: RS-485 Serial Communication
- Communication Protocol: Modbus RTU (Master/Slave)
- Number of Ports: 1 × RS-485 (2-wire half-duplex)
- Baud Rate: 9600, 19200, 38400, 57600, 115200 bps (selectable)
- Data Format: 8 data bits, 1 stop bit, No parity / Even parity / Odd parity (selectable)
- Max Communication Distance: 1200 m (at 9600 bps)
- Isolation Voltage: 500 VDC (between PLC bus and RS-485 port)
- Power Supply: 5 VDC from PLC backplane bus
- Current Consumption: 120 mA (typ.) from backplane
- Operating Temperature: 0°C to +55°C (+32°F to +131°F)
- Dimensions (W × H × D): 25 mm × 90 mm × 85 mm
- Weight: Approximately 0.08 kg
Functional Features:
- Supports Modbus RTU master and slave modes simultaneously
- Up to 32 Modbus registers for data exchange (configurable)
- Built-in termination resistor switch (120 Ω)
- LED indicators for TX, RX, and error status
- Hot-swappable from the PLC rack
Structural Features:
- Standard F3/F4 series module form factor
- DIN rail mountable within PLC rack
- Terminal block connector for RS-485 A/B lines
- Termination resistor DIP switch on module
Working Principle:
The module interfaces with the PLC CPU via the backplane bus. The CPU sends/receives Modbus RTU frames to/from the RS-485 port. The module handles all serial protocol timing, CRC calculation, and frame formatting. In master mode, the PLC polls slave devices; in slave mode, the module responds to queries from an external master. The RS-485 transceiver provides differential signaling for noise immunity over long cable runs.
Advantages & Highlights:
- Wide baud rate selection up to 115200 bps for high-speed data exchange
- Galvanic isolation of 500 VDC protects the PLC from ground loops and surges
- Dual-mode operation (master/slave) provides maximum integration flexibility
- Compact form factor fits standard F3/F4 PLC racks
Applicable Industries:
- All industries using F3/F4 series PLCs
- Building automation (BACnet-to-Modbus gateways)
- Water/wastewater SCADA integration
- Packaging machinery
Installation Requirements:
- Insert into the F3/F4 PLC rack at the designated slot position
- Set the termination resistor switch to ON for the last device on the RS-485 bus
- Use shielded twisted-pair cable (120 Ω characteristic impedance)
- Connect A (+) and B (-) terminals correctly; reverse polarity causes communication failure
Usage Precautions:
- Maximum 32 devices (including master) on a single RS-485 segment without repeaters
- Do not mix 2-wire and 4-wire RS-485 devices on the same bus
- Set the baud rate, parity, and stop bits identically on all devices on the bus
- Keep RS-485 cable away from high-power cables (minimum 200 mm separation)