Product Introduction:
The E204DN-AB1-LS A/FF1/FN1 is a multivariable smart transmitter from Yokogawa’s EJX series. This model simultaneously measures differential pressure, static pressure, and process temperature from a single process connection. The model code decodes as: E204DN = Multivariable type, AB1 = Output/configuration code, LS = Local display with backlight, A = HART 7 / FF1 = Flange-Flange process connection (DIN), FN1 = Drain/vent fitting. The wetted parts are constructed from Hastelloy C-276 for maximum corrosion resistance.

Detailed content

Technical Specifications:

  • Measurement TypeDifferential Pressure, Static Pressure, Process Temperature (3-variable simultaneous)
  • DP Range: 0 to 100 kPa (configurable, typical ranges: 0–2.5 kPa to 0–1000 kPa)
  • Static Pressure Range: 0 to 16 MPa (160 bar)
  • Temperature Range: -40°C to +120°C (process fluid)
  • Output Signal4 to 20 mA DC (HART 7, FF, or PA protocol selectable)
  • Accuracy (DP): ±0.04% of URL (Upper Range Limit)
  • Accuracy (Static Pressure): ±0.1% of span
  • Accuracy (Temperature)±0.1°C
  • Process Connection: FF1 — DIN flange-to-flange (DN50, PN40, RF face per DIN 2527)
  • Drain/VentFN1 — 1/2″ NPT female (bottom connection)
  • Wetted Material: Hastelloy C-276
  • Process Temperature (ambient)-40°C to +85°C
  • Protection RatingIP67 (IEC 60529)
  • Explosion ProofEx d IIC T6 Gb (ATEX), FM Class I Div 1, CSA Class I Div 1

Functional Features:

  • Simultaneous 3-variable measurement from a single process tap — eliminates need for separate instruments
  • Local LCD display shows all 3 process variables, bar graph, and device status
  • HART 7, FOUNDATION Fieldbus H1, Profibus PA protocol selectable
  • Built-in temperature sensor (Pt1000) for process temperature measurement
  • SIL 2 certified (IEC 61508) for safety instrumented functions

Performance Parameters:

Parameter Value
Turndown Ratio 100:1 (DP), 40:1 (SP)
Response Time ≤400 ms (DP, 90% step)
Overpressure Rating 1.5 × URL (static), 2.5 × URL (differential)
Ambient Temperature Effect ±0.1% URL per 28°C
Static Pressure Effect ±0.05% URL per 10 MPa
Long-term Stability ±0.1% URL per 5 years
Supply Voltage 12 to 45 V DC (HART), 15.4 to 42.4 V DC (FF/PA)

Material Composition:

  • Wetted Parts: Hastelloy C-276 (UNS N10276) — superior resistance to chlorides, sulfuric acid, and mixed acids
  • Diaphragm Seal: Hastelloy C-276 with fluorocarbon (FKM) O-ring
  • Housing: Aluminum alloy (AL6063-T5) with epoxy polyester powder coat (RAL 5010)
  • Cable Gland: 316L Stainless Steel with nickel plating

Structural Characteristics:

  • Dimensions: 168 mm (H) × 118 mm (W) × 155 mm (D) (excluding flanges)
  • Weight: Approximately 6.5 kg (with FF1 flanges)
  • Flange Dimensions: DN50 (2″), PN40, RF face, bolt circle 110 mm, 4 × M12 bolts
  • Display: 128 × 64 pixel LCD with white backlight, 4-line text + bar graph

Working Principle:
The transmitter uses a resonant silicon sensor for differential pressure and static pressure measurement. The silicon diaphragm vibrates at its natural resonant frequency (~100 kHz), which shifts proportionally to applied pressure. A capacitive pick-off detects the frequency shift and converts it to a digital pressure value. The integrated Pt1000 RTD measures process temperature via 4-wire resistance measurement. The microprocessor fuses all 3 variables using proprietary algorithms to compensate for temperature effects on DP and SP readings. The result is transmitted as 4–20 mA + HART digital signal.

Key Advantages:

  • Hastelloy C-276 wetted parts — handles the most aggressive chemical processes (HCl, H2SO4, acetic acid, chlorides)
  • 3-variable measurement from single connection — reduces process penetrations by 66%
  • SIL 2 / SIL 3 capable — suitable for safety-critical applications
  • DIN flange connection (FF1) — standard European piping compatibility

Applicable Industries:

  • Chlor-alkali plants (chlorine gas, caustic soda)
  • Sulfuric acid production
  • Pharmaceutical reactor monitoring (aggressive solvents)
  • Offshore oil and gas (seawater injection)
  • Pulp and paper digester monitoring

Installation Requirements:

  • Install vertical or inclined (process connection at bottom) for liquid service
  • For gas service, install process connection at top or side with vent at top
  • Use DN50 PN40 DIN flanges with spiral wound gasket (graphite + 316L)
  • Connect drain/vent (FN1) to closed collection system for hazardous fluids
  • Bond the transmitter housing to plant ground (impedance < 1 Ω)

Usage Precautions:

  • Do not exceed 16 MPa static pressure — will permanently deform the silicon sensor
  • Do not apply pressure to the drain/vent (FN1) fitting when process is pressurized
  • Perform zero calibration with both process connections at equal pressure (for DP)
  • Replace diaphragm seals every 5 years in corrosive service (even with Hastelloy C-276)
  • Verify HART communication address is unique on the loop before commissioning