Digital guide

You are here:

Yokogawa DX220‑3‑2

  • Product Name: DX220‑3‑2 DAQSTATION Digital Paperless Recorder
  • Product Series: Yokogawa DX Series Panel‑Mount Data Recorder
  • Product Brief: High‑precision industrial paperless recorder for real‑time data acquisition, display, recording and storage of process parameters

Detailed content

  • Technical Specifications:
    • Input Channels: Max 20 universal analog input channels
    • Input Signal Types: DC voltage, standard current signal (4–20 mA), thermocouple, RTD resistance thermometer, contact signal
    • Measurement Accuracy: ±0.1% FS (voltage/current), ±0.1°C (temperature signal)
    • Sampling Speed: 100 ms minimum per channel
    • Power Supply: 100–240 VAC, 50/60 Hz
    • Storage Capacity: 400 MB built‑in memory, support external USB storage expansion
    • Communication Interface: Standard Ethernet, RS‑422, support Modbus‑TCP, PROFIBUS‑DP protocols
    • Dimensions (W×H×D): 288 mm × 288 mm × 220 mm
    • Weight: 8.39 kg
  • Functional Features: Real‑time curve display, historical data query, batch recording, automatic report generation, email/FTP data push, 21 CFR Part 11 compliance security function
  • Performance Advantages: IP65 dust‑proof and splash‑proof front panel, high anti‑interference capability, long‑term stable continuous operation, low maintenance cost
  • Material Composition: Front bezel: Polycarbonate; Main housing: Cold‑rolled steel plate with anti‑corrosion coating
  • Structural Characteristics: Panel‑mount embedded structure, front panel lockable design
  • Working Principle: Collect industrial analog/digital signals through built‑in high‑speed A/D converter, convert to digital data for real‑time display, storage and transmission
  • Applicable Industries: Chemical, energy, food processing, pharmaceutical, environmental monitoring, manufacturing process parameter recording
  • Installation Requirements: Panel thickness 2–26 mm embedded installation, reserved heat dissipation gap around the equipment
  • Usage Precautions: Avoid direct water splashing on front panel; regular calibration of input channels per industrial standards