Digital guide

You are here:

YOKOGAWA DU200-11

Product Introduction:
The DU200-11 is a 1-channel universal input paperless recorder from Yokogawa’s DU200 series. It is the most compact and cost-effective model in the DX/DU recorder lineup. The 11 suffix indicates: 1 = 1 input channel / 1 = basic alarm configuration (1 alarm output). The DU200 replaces chart recorders with digital recording, data storage, and alarm functions in a 1/8 DIN (96 × 48 mm) form factor.

Detailed content

Technical Specifications:

  • Number of Input Channels1 channel (universal input)
  • Input TypesTC (J, K, T, E, B, R, S, L, N, W) / RTD (Pt100, JPt100, Cu50) / DC Voltage (0–5V, 1–5V, 0–10V) / DC Current (4–20mA, 0–20mA) / Frequency (1Hz–10kHz)
  • Recording Speed: 0.5 sec to 60 sec per scan
  • Display: 5-digit, 7-segment LED (red for PV, green for SV)
  • Alarm Output: 1 alarm output (HIGH, LOW, DEVIATION, RATE)
  • Transmitter Output: None (basic model) / Optional on some variants
  • Communication: None (standalone) — RS-232C optional on some variants
  • Power Supply100–240 VAC, 50/60 Hz / 24 VDC
  • Power Consumption: Maximum 5 VA
  • Recording MemoryInternal flash memory, approximately 60 days at 0.5 sec scan (1 channel)
  • Operating Temperature: 0 to +50 °C (32 to 122 °F)
  • Protection Rating: Front panel IP54 / NEMA4 (when gasketed)
  • Dimensions48 mm (W) × 96 mm (H) × 83 mm (D) (1/8 DIN: 45 × 90 mm cutout)
  • Weight: Approximately 0.25 kg

Functional Features:

  • Universal input — auto-detects all input types
  • 1 configurable alarm with setpoint, hysteresis, and delay
  • Bar graph display for trend visualization
  • PV tracking display (manual mode follows PV)
  • Password protection (2-level access)
  • Data hold function — freeze display on alarm
  • Scaling function — engineering unit conversion (e.g., °C to °F, mA to engineering units)

Performance Parameters:

  • Input Accuracy (TC)±0.3% of reading ±1 digit (K-type)
  • Input Accuracy (RTD)±0.3% of reading ±1 digit (Pt100)
  • Input Accuracy (mA): ±0.2% of span ±1 digit
  • Alarm Response Time: ≤ 200 ms
  • Display Update Rate: 1 second

Structural Features:

  • HousingABS resin (UL94 V-0), snap-on front panel
  • Terminal Block: Screw terminal, wire size 0.5–2.5 mm² (AWG 20–14)
  • Mounting1/8 DIN panel clip or DIN rail (35 mm)

Applicable Industries:

  • Small Process Plants — Single temperature or pressure monitoring
  • HVAC — Room temperature recording
  • Food & Beverage — Single-point temperature monitoring
  • Water Treatment — Tank level or temperature recording
  • OEM Equipment — Embedded recording in machines

Installation Requirements:

  • Panel cutout: 45 mm (W) × 90 mm (H) for 1/8 DIN mounting
  • Use correct thermocouple extension wire for TC inputs
  • Use 3-wire RTD configuration for best accuracy
  • Keep input wiring away from high-current cables (minimum 50 mm separation)

Precautions:

  • Do not apply more than 30 VDC or 250 VAC between any input terminals
  • Do not exceed rated input range — will cause permanent damage
  • Ensure proper grounding of the recorder chassis
  • Backup data to USB drive periodically — internal memory has limited write cycles