YOKOGAWA DU200-11
Product Introduction:
The DU200-11 is a 1-channel universal input paperless recorder from Yokogawa’s DU200 series. It is the most compact and cost-effective model in the DX/DU recorder lineup. The 11 suffix indicates: 1 = 1 input channel / 1 = basic alarm configuration (1 alarm output). The DU200 replaces chart recorders with digital recording, data storage, and alarm functions in a 1/8 DIN (96 × 48 mm) form factor.
Detailed content
Technical Specifications:
- Number of Input Channels: 1 channel (universal input)
- Input Types: TC (J, K, T, E, B, R, S, L, N, W) / RTD (Pt100, JPt100, Cu50) / DC Voltage (0–5V, 1–5V, 0–10V) / DC Current (4–20mA, 0–20mA) / Frequency (1Hz–10kHz)
- Recording Speed: 0.5 sec to 60 sec per scan
- Display: 5-digit, 7-segment LED (red for PV, green for SV)
- Alarm Output: 1 alarm output (HIGH, LOW, DEVIATION, RATE)
- Transmitter Output: None (basic model) / Optional on some variants
- Communication: None (standalone) — RS-232C optional on some variants
- Power Supply: 100–240 VAC, 50/60 Hz / 24 VDC
- Power Consumption: Maximum 5 VA
- Recording Memory: Internal flash memory, approximately 60 days at 0.5 sec scan (1 channel)
- Operating Temperature: 0 to +50 °C (32 to 122 °F)
- Protection Rating: Front panel IP54 / NEMA4 (when gasketed)
- Dimensions: 48 mm (W) × 96 mm (H) × 83 mm (D) (1/8 DIN: 45 × 90 mm cutout)
- Weight: Approximately 0.25 kg
Functional Features:
- Universal input — auto-detects all input types
- 1 configurable alarm with setpoint, hysteresis, and delay
- Bar graph display for trend visualization
- PV tracking display (manual mode follows PV)
- Password protection (2-level access)
- Data hold function — freeze display on alarm
- Scaling function — engineering unit conversion (e.g., °C to °F, mA to engineering units)
Performance Parameters:
- Input Accuracy (TC): ±0.3% of reading ±1 digit (K-type)
- Input Accuracy (RTD): ±0.3% of reading ±1 digit (Pt100)
- Input Accuracy (mA): ±0.2% of span ±1 digit
- Alarm Response Time: ≤ 200 ms
- Display Update Rate: 1 second
Structural Features:
- Housing: ABS resin (UL94 V-0), snap-on front panel
- Terminal Block: Screw terminal, wire size 0.5–2.5 mm² (AWG 20–14)
- Mounting: 1/8 DIN panel clip or DIN rail (35 mm)
Applicable Industries:
- Small Process Plants — Single temperature or pressure monitoring
- HVAC — Room temperature recording
- Food & Beverage — Single-point temperature monitoring
- Water Treatment — Tank level or temperature recording
- OEM Equipment — Embedded recording in machines
Installation Requirements:
- Panel cutout: 45 mm (W) × 90 mm (H) for 1/8 DIN mounting
- Use correct thermocouple extension wire for TC inputs
- Use 3-wire RTD configuration for best accuracy
- Keep input wiring away from high-current cables (minimum 50 mm separation)
Precautions:
- Do not apply more than 30 VDC or 250 VAC between any input terminals
- Do not exceed rated input range — will cause permanent damage
- Ensure proper grounding of the recorder chassis
- Backup data to USB drive periodically — internal memory has limited write cycles