The SCXI-1163R is a 32-channel relay switching module built for the SCXI (Signal Conditioning eXtensions for Instrumentation) system. It uses optically isolated solid-state relays arranged as Form A (normally open) contacts, grouped into eight groups of four relays, with each group sharing a common pole. The module is intended for switching high-voltage loads and for low-speed digital signal control.

Detailed content

Technical Specifications‌

  • Channel count: 32 output channels
  • Relay type: Solid-state relay (SSR), Form A (normally open)
  • Relay grouping: 8 groups of 4 relays, each group with a common pole
  • Maximum switching voltage: 240 V AC or DC
  • Maximum switching current: 200 mA per channel
  • Isolation voltage: 450 V between channel groups, and between groups and ground
  • Leakage current: approximately 1 µA typical
  • Turn-on time: approximately 1.5 ms
  • Turn-off time: approximately 0.25 ms
  • Connector type: standard 48-pin DIN connector
  • Bus interface: SCXI bus, serial programming
  • Part number: 776572-63R

‌Functional Features‌

  • No mechanical contacts, giving very long service life and eliminating contact wear and oxidation
  • High channel density: 32 channels in a single SCXI slot
  • Optical isolation for strong noise immunity
  • Independent control of every channel
  • Suited to switching operations that do not demand high switching speed

‌Application Scenarios‌

  • Automated test equipment (ATE)
  • Industrial control systems
  • Remote voltage switching
  • Switching control of high-voltage devices within data acquisition systems

‌Operating Principle‌
Each channel is a normally open solid-state relay switched by control logic; when a channel is activated, the optically isolated semiconductor path closes to connect the high-voltage load. Grouping four relays under a common pole allows shared-return switching configurations.

‌Material and Structural Composition‌
A card-format module for the SCXI chassis, populated with optically coupled solid-state relay devices and a 48-pin DIN front connector, with an SCXI bus edge connector for communication.

‌Installation Requirements‌
Installs in any SCXI chassis slot; the chassis power must be switched off before insertion. Direct wiring to a digital I/O device is possible when parallel operation is required.