Digital guide

You are here:

NI PCI-4462

Product Overview‌

The PCI-4462 is a high-accuracy data acquisition module specifically designed for sound and vibration applications. It provides simultaneous four-channel dynamic signal acquisition with six programmable gain settings for making high-accuracy frequency-domain measurements. It includes software-configurable AC/DC coupling and integrated electronic piezoelectric (IEPE) conditioning for precision measurements with microphones, accelerometers and other transducers having very large dynamic ranges. Part number 779309-01.

Detailed content

Technical Specifications‌

Resolution 24-bit sigma-delta ADC. Maximum sampling rate 204.8 kS/s. Dynamic range 118 dB. Four simultaneous analog input channels. Input range plus or minus 316 mV to 42.4 V with six gain settings. Coupling 3.4 Hz AC/DC coupled. Input impedance 1 M-ohm in parallel with 240 pF, pseudo-differential. Current noise less than 300 pA per root hertz. IEPE current 0, 4 or 10 mA, independently selectable per channel. Bus interface PCI. Onboard anti-aliasing filter. TEDS compatible with IEEE 1451. Dimensions 107.95 mm by 168.4 mm. Weight approximately 0.5 kg.

‌Functional Features‌

High-precision measurement through a 24-bit sigma-delta ADC. High dynamic range suited to microphones, accelerometers and other transducers with very large dynamic ranges. Multi-channel synchronous acquisition with the ability to synchronize with other PCI-4462 boards or other DSA boards. Software-selectable IEPE conditioning and AC/DC coupling. Built-in anti-aliasing filter. Support for multiple trigger modes including software and hardware triggering. Multiple programming environments including LabVIEW, C/C++ and MATLAB.

‌Application Scenarios‌

Audio test and audio spectrum analysis. Automotive test and NVH (noise, vibration and harshness) analysis. Machine condition monitoring and predictive maintenance. Noise emission testing and sound holography. Vibration analysis and structural health monitoring in mechanical engineering, aerospace and electronics.

‌Performance Parameters‌

Full-scale accuracy is provided by the 24-bit conversion combined with six gain settings. The device supports synchronization with PCI-4461 and PXI-4462 devices to build multi-channel systems. The system operates under NI-DAQmx driver software.

‌Material Composition‌

Standard PCI printed circuit board assembly with BNC front connectivity, industrial-grade components and integrated signal conditioning circuitry.

‌Structural Characteristics‌

Standard PCI board format with BNC front connectors. Differential or pseudo-differential input configuration referenced to chassis ground through 50 ohms, independently selectable per channel. Suitable for installation in standard PCI slots.

‌Working Principle‌

External analog signals from microphones or accelerometers are conditioned through software-configurable AC/DC coupling and IEPE current excitation, then converted by a 24-bit sigma-delta analog-to-digital converter. Onboard anti-aliasing filters and programmable gain stages ensure signal purity, and the digitized data is transferred to the host for frequency-domain and time-domain analysis.

‌Installation Requirements‌

Verify that the installation environment meets the operating temperature range and storage temperature range before installation. Use a standard PCI slot to ensure stable and reliable mounting. Provide adequate cabinet ventilation.