Honeywell 51309204-175

  • Product Name: MC-TLPA02 24 VDC Power Adapter (Size A) for LLMux / SDI / SI
  • Product Introduction: This is a CE-compliant, conformal-coated power adapter board that provides power and the IOP-to-FTA interface for up to two LLMux FTAs (each FTA = 16 channels, total 32 channels). It mounts in the FTA tray inside a cabinet or a NEMA 12 box and serves as a critical interface between Serial Device Interface (SDI) I/O Processors (IOPs) and remote FTAs in xPM cabinet installations.

Detailed content

  • Technical Specifications:
    • Type: 24 VDC Power Adapter Module for LLMux/SDI/SI
    • Rating: 24 VDC, 110 mA
    • Input Voltage Range: 85–265 VAC
    • Output: 24 VDC, up to 25 A (per some supplier data)
    • Form Factor: Size A, approx. 6 inches
    • Mounting: FTA tray / cabinet / NEMA 12 box; rack or panel mount
    • Connectors: Compression terminal connectors
    • Weight: 1.5 kg
    • Country of Origin: USA
  • Functional Features: Delivers stable 24 VDC power to FTA modules. Uses compression terminal connectors and MU-KFTAxx / MU-KFTSxx interconnection cables. Supports internal cabinet installation (using 51304465-xxx shielded cable, 30–300 cm) and external remote cabinet installation up to 300 m.
  • Application Scenarios: Powers logic modules, I/O processors, and communication interfaces in Honeywell LLMux, SDI, and SI distributed control systems. Applied in oil & gas, chemical processing, and power generation.
  • Structural & Material Characteristics: Size A PCB-form factor (approx. 6 inches). CE-compliant version with conformal coating for harsh environments. Industrial-grade components.
  • Working Principle: Converts incoming AC mains (85–265 VAC) to regulated 24 VDC output, distributing power to connected FTA modules via compression terminals while providing the signal interface between IOP and FTA.
  • Installation Requirements: Mount in FTA tray inside a cabinet or NEMA 12 enclosure. Use compression terminals for wiring. For internal cabinet setups, use 51304465-xxx shielded cable (30–300 cm). For external/remote mounting up to 300 m, use MU-KLXxxx shielded cables with proper grounding at both ends.
  • Usage Notes: Ground shielding correctly—internal cables ground only at the Power Adapter end; external MU-KLXxxx cables require grounding at both ends. Ensure the 24 VDC rating (110 mA) vs. output current capacity is matched to load. Verify all connections before energizing.