Genteq 5KCP39PG Series Permanent Split Capacitor Industrial Motor
Product Overview​
The 5KCP39PG prefix covers Genteq OEM replacement alternating-current motors produced under Regal Rexnord. The verified configuration 5KCP39PGU719S is a 48-frame, 5.6-inch diameter motor built for air-over blower and fan duties. The same 5KCP39PG family also includes other suffixes with different voltage, speed and horsepower ratings, so the nameplate suffix defines the exact electrical data.

Detailed content

Technical Specifications​
Configuration 5KCP39PGU719S: single-phase, 1/2 hp, 460 VAC, 60 Hz, 1050 rpm, 1 speed
Electrical type: permanent split capacitor
Poles: 6
Frame: 48
Enclosure: totally enclosed air over
Thermal protection: thermally protected
Insulation class: B
Ambient temperature: 60°C
Service factor: 1
Current: 0.90 A for the 460 V / 1/2 hp configuration
Rotation: reversible
Mounting: extended studs, belly band, extended clamp bolts
Bearings: ball bearing on drive end and opposite drive end
Shaft: 1/2 inch diameter with flat and groove, 2.92 inch extension
Overall length: 9.13 inches
Frame length: 5.07 inches
Weight: 17.50 lb
Leads: 28 inch wire leads
Certifications: UL recognized, CSA listed
Alternative Suffix Data​
5KCP39PGV554S: single-phase, 3/4 hp, 230/460 VAC, 1075 rpm, 48-frame direct-drive motor
Other 5KCP39PG distribution-motor variants are listed by third-party suppliers at 208 to 230 VAC, 3/4 hp and 1075 rpm for HVAC blower service; exact current, capacitor and rotation must be taken from the motor nameplate.
Functional Features​
Permanent split capacitor circuit for single-speed fan and blower operation
Totally enclosed air-over construction for installations with continuous airflow across the frame
Ball bearings for sustained rotation under industrial duty
Reversible rotation selected during electrical connection and mechanical assembly
Extended studs and belly-band mounting for direct replacement in OEM blower housings
Application Scenarios​
HVAC air handlers and furnace blowers
Industrial ventilation units with air-over cooling
OEM replacement of 48-frame blower motors
Continuous-duty fan circuits where enclosed motors are required
Performance Parameters​
Rated speed: 1050 rpm for 460 V / 1/2 hp configuration, 1075 rpm for listed 230/460 V and 208/230 V variants according to suffix
Rated output: 0.37 kW for 1/2 hp configuration, 0.56 kW for 3/4 hp configurations
Duty: continuous air-over
Enclosure cooling: external airflow must pass over the motor shell in totally enclosed air-over duty
Material Composition​
Frame: rolled steel
Shaft: steel with flat and groove
Bearings: precision ball bearings
Windings: copper or aluminum conductors with Class B insulation system
External hardware: steel studs, clamps and belly-band kit according to mounting variant
Structural Characteristics​
5.6-inch diameter 48-frame round body
End brackets with extended studs or bracket mounts according to suffix
Single shaft extension with flat and groove
Terminal leads rather than terminal box for OEM replacement versions
Working Principle​
The single-phase supply energizes the run winding and the permanent split capacitor feeds the auxiliary winding with phase-shifted current. The rotating magnetic field drives the rotor at synchronous-related speed reduced by slip. In air-over duty, ventilation air from the connected blower removes heat from the enclosed frame so the motor sustains continuous rated load.
Installation Requirements​
Verify the complete nameplate suffix before wiring; 460 V, 230/460 V and 208/230 V versions are not interchangeable without supply and protection review.
Provide continuous airflow over the frame for totally enclosed air-over ratings.
Use 48-frame mounting studs, brackets or belly band specified for the replacement model.
Confirm shaft diameter, shaft length and rotation direction against the blower wheel.
Ground the motor according to the equipment electrical drawing.
Usage Notes​
Do not operate without forced air in air-over enclosures.
Replace thermal protection only with the same trip rating.
Check bearing condition and shaft runout before returning the motor to service.
Match capacitor value to the nameplate when a separate run capacitor is required.