Model Series: TC-52 Series (Dual-Channel Peak Torque Grade)

Product Overview:
The TC-52P-P is a dual-channel peak torque controller where both channels share the 1–52 Nm range. The “P-P” designation confirms two independent peak torque outputs, enabling dual-step or dual-axis fastening from a single compact unit.

Detailed content

Technical Specifications:

  • Torque Range (per channel): 0.2 – 52 Nm
  • Torque Accuracy: ±3% of reading (per channel)
  • Repeatability: ±1% of reading (per channel)
  • Control Mode: Dual Peak Torque (P-P)
  • Power Supply: 24 V DC
  • Communication: 4 digital I/O, RS-232 optional
  • Operating Temperature: 0°C to +45°C
  • Protection Rating: IP54

Functional Features:

  • Two fully independent peak torque channels (A and B)
  • Independent teach-in per channel
  • Sequential or simultaneous operation mode
  • Per-channel LED pass/fail indication
  • Total cycle counter
  • Buzzer on completion of both channels

Structural Characteristics:

  • Housing: PA66-GF30, 140 x 90 x 50 mm
  • Dual 4-digit LED displays
  • 6 membrane buttons (3 per channel)
  • Two M12 8-pin screwdriver connectors
  • DIN rail clip included

Material Composition:

  • Housing: PA66-GF30
  • PCB: FR-4 with conformal coating
  • Connectors: PBT, gold-plated
  • Mounting: Stainless steel AISI 304 clip

Working Principle:
Channel A and Channel B each independently monitor torque from their respective screwdrivers. In sequential mode, Channel A completes first, then Channel B fires. In simultaneous mode, both channels operate in parallel. Each channel cuts its tool power upon reaching its individual peak torque setpoint.

Key Advantages:

  • Two fastening points controlled by one unit — reduces hardware count
  • Enables two-step tightening (e.g., pre-torque + final torque) on a single joint
  • Cost savings versus two separate TC-52P units
  • Compact dual-channel design

Applicable Industries:
Automotive interior trim, Electronic chassis assembly, Pump assembly, Valve assembly

Installation Requirements:

  • DIN rail or panel mount
  • 24 V DC, minimum 3 A (dual channel)
  • Two M12 8-pin cables (max. 3 m each)
  • 50 mm separation from VFD/welding equipment

Usage Precautions:

  • Calibrate each channel independently — do not assume symmetry
  • Do not exceed 52 Nm on either channel
  • Verify both channels before each production run
  • Clean both M12 connectors weekly in dusty environments