ATLAS COPCO PF4002-C-EIP-HW

Product Name: Atlas Copco PF 4002 C EIP HW Compressed Air Precision Filter with Electronic Drain

Model Series: PF 4000 Series

Product Type: Compressed air line filter — coarse particle removal with automated drain

Filtration Grade1 μm (particle removal)

Detailed content

Nominal Flow Rate: 4,000 L/min (4.0 m³/min) at 7 bar inlet pressure

Maximum Operating Pressure16 bar (232 psi)

Maximum Operating Temperature+50 °C (+122 °F)

Connection TypeG 1″ (BSP thread) — designation “C”

Drain Type: Electronic interval purge drain (EIP) — automated condensate discharge at programmable intervals

Housing MaterialAnodized aluminum alloy (AlSi10Mg)

Filter Element MaterialSintered bronze / sintered metal

Differential Pressure IndicatorNot equipped (standard)

Pressure GaugeNot equipped (standard)

Electronic Drain Specification230 V AC / 24 V DC; adjustable purge cycle; failsafe normally-open solenoid valve; power loss triggers automatic drain open

Dimensions (Approximate): Length 310 mm × Diameter 138 mm

Weight (Approximate): 4.1 kg (including electronic drain assembly)

Function: High-flow compressed air particle filtration with zero-maintenance condensate removal via electronic timer drain

Applicable Industries: All standard PF4002 applications; centralized compressed air plants; remote installations; 24/7 production facilities

Installation Requirement: Install vertically with drain valve at bottom; provide electrical connection for EIP module (230 V AC or 24 V DC); maintain 100 mm clearance around drain module for ventilation

Usage Notes: EIP purge interval is factory-set at 30 minutes default; adjustable via external controller; each purge cycle lasts approximately 5 seconds; typical condensate volume per cycle: 10–50 mL depending on system conditions

Advantage over PF4002-C-HW: Eliminates all manual drain intervention; reduces compressed air waste by 95% compared to manual blow-down; extends filter element life by maintaining consistent downstream pressure


CROSS-REFERENCE SUMMARY TABLE

Model Flow (L/min) Filter Grade Housing Drain Gauge Diff. Indicator Special Feature
PF4002-C-HW 4,000 1 μm Aluminum Manual (HW) No No Standard
PF-3110S-S4/7 1,100 0.01 μm 316L SS Manual No No Hygienic / Sterile
PF-4002-C-EIP-HW 4,000 1 μm Aluminum Electronic (EIP) No No Auto drain
PF3009-G-IB-HW 900 1 μm Aluminum Manual (HW) Yes (G) Yes (IB) Gauge + Indicator
PF-4000-C-DN-HW 4,000 1 μm Aluminum Manual (HW) No Yes (DN) Diff. Indicator
PF4002-C-DN-HW 4,000 1 μm Aluminum Manual (HW) No Yes (DN) Diff. Indicator
PF3107-C-IB2-HW 1,050 1 μm Aluminum Manual (HW) No Yes (IB2) Dual Indicator
PF3107-G-EIP-HW 1,050 1 μm Aluminum Electronic (EIP) Yes (G) No Gauge + Auto Drain
PF3110-S-S4/S7 1,100 0.01 μm 316L SS Manual No No Hygienic / Sterile
PF4002-C-EIP-HW 4,000 1 μm Aluminum Electronic (EIP) No No Auto drain

COMMON TECHNICAL SPECIFICATIONS (ALL MODELS)

Parameter Value
Max Inlet Pressure 16 bar (232 psi)
Max Operating Temperature +50 °C (+122 °F)
Standard Connection G 1″ BSP (ISO 228/1)
Housing Standard Material AlSi10Mg anodized aluminum (standard); AISI 316L stainless steel (S-series)
Filter Element Standard Sintered metal (1 μm); Coalescing fiber / activated carbon (0.01 μm)
Differential Indicator Activation 0.5 bar pressure drop
Electronic Drain Voltage 230 V AC / 24 V DC
Electronic Drain Failsafe Normally open — drains on power loss
Recommended Service Interval 4,000 operating hours or when differential indicator activates (whichever comes first)

INSTALLATION REQUIREMENTS (UNIVERSAL)

Orientation: All PF series filters must be installed vertically with the drain valve at the lowest point

Clearance: Minimum 300 mm above the filter for element replacement access

Piping: Use galvanized steel, stainless steel, or aluminum piping; avoid copper (contamination risk)

Upstream Protection: Install a coalescing separator or aftercooler upstream to reduce moisture and oil load on the filter element

Downstream: Install a check valve downstream if the filter serves a critical process to prevent backflow

Electrical (EIP models): Provide dedicated circuit; verify voltage before connection; EIP module must be mounted in a location with ambient temperature below +50 °C


MAINTENANCE NOTES

Action Interval / Trigger
Element Replacement Every 4,000 hours or when differential indicator turns red (0.5 bar ΔP)
Drain Valve Service (HW) Every 6 months; clean seat and replace seal if leaking
Electronic Drain (EIP) Check solenoid operation quarterly; clean drain orifice annually
Housing Inspection (S-series) Inspect welds and surface finish annually; verify Ra ≤ 0.8 μm
Gauge Calibration Annually or per facility quality standard