Product Introduction: The PF3102-C-HW is a Generation 2 platform compressor delivering 31 m³/min of compressed air in a compressor-only (C) configuration. The “02” indicates Generation 2 architecture — an earlier platform design with proven reliability and simplified maintenance. The “HW” suffix confirms high-altitude capability. This model serves markets where the Generation 2 platform remains in active service due to parts availability and lower acquisition cost.
Detailed content
Technical Specifications:
| Parameter | Value |
|---|---|
| Free Air Delivery (FAD) | 31.0 m³/min (1,095 cfm) |
| Working Pressure Range | 7 – 13 bar (101 – 188 psi) |
| Rated Pressure | 13 bar (188 psi) |
| Engine Model | Deutz TCD 2013 L04 2V (Gen 2 spec) |
| Engine Power | 250 kW (335 hp) at 1,800 rpm |
| Generator | None (C Configuration) |
| Compressor Element | Atlas Copco GA 31 airend (Gen 2) |
| Cooling System | Air-cooled |
| Fuel Tank Capacity | 600 L (159 US gal) |
| Operating Weight | 10,000 kg (22,046 lbs) |
| Dimensions (L×W×H) | Approx. 5,250 × 2,150 × 2,400 mm |
| Noise Level (at 7m) | ≤ 95 dB(A) |
| Emissions Compliance | EPA Tier 3 / EU Stage IIIA (Gen 2 rated) |
Material Composition:
- Chassis: S355 structural steel, hot-dip galvanized
- Engine: Deutz TCD 2013 L04 2V — Generation 2 emission specification
- Airend: GA 31 Gen 2 with 5:6 rotor profile
- Canopy: Single-wall galvanized steel with basic acoustic liner
Structural Features:
- Single-axle towable chassis
- 4 hydraulic stabilizer legs
- Standard forklift pockets (4 points)
- Towbar with 50mm pintle hitch
- Basic canopy design (no sound-attenuated dual canopy)
Working Principle: The Deutz TCD 2013 L04 2V engine drives the GA 31 Gen 2 airend via flexible coupling. Oil-injected rotary screw compression delivers air at 7–13 bar. The Generation 2 control system uses the Elektronikon Basic controller (non-touchscreen) with LED indicator panel. Cooling is air-cooled only — no water circuit.
Key Advantages:
- Lowest acquisition cost in the 31 m³/min class
- Generation 2 platform with extensive global parts availability
- Simplified maintenance — fewer electronic components
- HW-rated chassis supports high-altitude deployment
Applicable Industries: Cost-sensitive rental markets, developing regions, secondary construction sites, well drilling, paint spraying
Installation Requirements:
- Level surface with ≥ 11 tonnes/m² capacity
- 2.5m service clearance
- Basic 400V single-phase or 3-phase connection for control panel
Usage Precautions:
- Gen 2 emission rating — verify local emission regulations before deployment in restricted zones
- Elektronikon Basic controller has no remote monitoring — manual reading required
- Service interval: 500 hours (engine oil), 2,000 hours (airend service)
- Air filter change: every 250 hours
- Maximum continuous operation: 12 hours before mandatory cool-down (air-cooled only)