Product Introduction: The PF3102-C-HW is a Generation 2 platform compressor delivering 31 m³/min of compressed air in a compressor-only (C) configuration. The “02” indicates Generation 2 architecture — an earlier platform design with proven reliability and simplified maintenance. The “HW” suffix confirms high-altitude capability. This model serves markets where the Generation 2 platform remains in active service due to parts availability and lower acquisition cost.

Detailed content

Technical Specifications:

Parameter Value
Free Air Delivery (FAD) 31.0 m³/min (1,095 cfm)
Working Pressure Range 7 – 13 bar (101 – 188 psi)
Rated Pressure 13 bar (188 psi)
Engine Model Deutz TCD 2013 L04 2V (Gen 2 spec)
Engine Power 250 kW (335 hp) at 1,800 rpm
Generator None (C Configuration)
Compressor Element Atlas Copco GA 31 airend (Gen 2)
Cooling System Air-cooled
Fuel Tank Capacity 600 L (159 US gal)
Operating Weight 10,000 kg (22,046 lbs)
Dimensions (L×W×H) Approx. 5,250 × 2,150 × 2,400 mm
Noise Level (at 7m) ≤ 95 dB(A)
Emissions Compliance EPA Tier 3 / EU Stage IIIA (Gen 2 rated)

Material Composition:

  • Chassis: S355 structural steel, hot-dip galvanized
  • Engine: Deutz TCD 2013 L04 2V — Generation 2 emission specification
  • Airend: GA 31 Gen 2 with 5:6 rotor profile
  • Canopy: Single-wall galvanized steel with basic acoustic liner

Structural Features:

  • Single-axle towable chassis
  • 4 hydraulic stabilizer legs
  • Standard forklift pockets (4 points)
  • Towbar with 50mm pintle hitch
  • Basic canopy design (no sound-attenuated dual canopy)

Working Principle: The Deutz TCD 2013 L04 2V engine drives the GA 31 Gen 2 airend via flexible coupling. Oil-injected rotary screw compression delivers air at 7–13 bar. The Generation 2 control system uses the Elektronikon Basic controller (non-touchscreen) with LED indicator panel. Cooling is air-cooled only — no water circuit.

Key Advantages:

  • Lowest acquisition cost in the 31 m³/min class
  • Generation 2 platform with extensive global parts availability
  • Simplified maintenance — fewer electronic components
  • HW-rated chassis supports high-altitude deployment

Applicable Industries: Cost-sensitive rental markets, developing regions, secondary construction sites, well drilling, paint spraying

Installation Requirements:

  • Level surface with ≥ 11 tonnes/m² capacity
  • 2.5m service clearance
  • Basic 400V single-phase or 3-phase connection for control panel

Usage Precautions:

  • Gen 2 emission rating — verify local emission regulations before deployment in restricted zones
  • Elektronikon Basic controller has no remote monitoring — manual reading required
  • Service interval: 500 hours (engine oil), 2,000 hours (airend service)
  • Air filter change: every 250 hours
  • Maximum continuous operation: 12 hours before mandatory cool-down (air-cooled only)