Digital guide

You are here:

AEG 6051-042.23602

Product Name: AEG 6051-042.23602 Drain Pump Motor Assembly

Product Category: Pump Motor / Drainage Pump Component

Model Series: 6051 Series OEM Pump

Overview: The AEG 6051-042.23602 is an original drain pump motor assembly used in AEG washing machines, washer-dryer combos, and dishwashers. It is responsible for pumping out wash water, rinse water, and drained condensate from the appliance.

Detailed content

Key Specifications:

Parameter Value
Part Number 6051-042.23602
Motor Type Single-Phase Asynchronous (Induction) Motor
Rated Voltage 220–240 V AC / 50 Hz
Rated Power 25 W – 40 W (depending on application)
Rated Speed 2,800 – 3,200 RPM
Max Flow Rate 1.2 L/min (at zero head)
Max Head Pressure 0.8 – 1.2 m (80–120 cm)
Hose Connection 18–22 mm internal diameter (barbed fitting)
Noise Level ≤ 55 dB(A)
Protection Class IPX4 (splash-proof)
Insulation Class Class B (130°C)
Bearing Type Sleeve bearing (oil-lubricated, maintenance-free)
Dimensions Approximately 100 × 80 × 95 mm (L×W×H)
Weight Approximately 0.65 kg
Cable Length 900 mm with molded connector

Material Composition:

  • Housing: Polypropylene (PP) + glass fiber reinforced (30% GF)
  • Impeller: Polypropylene (PP) — corrosion-resistant
  • Motor Stator: Laminated silicon steel with copper windings
  • Shaft: Stainless steel AISI 304
  • Seal: EPDM rubber mechanical seal

Compatible Models: AEG L6FBG842, L7FBG842, L8FBG842 washing machines; AEG FSB52637P dishwashers; AEG DEA156, DEA180 dehumidifiers (condensate drain variant).

Functional Features:

  • Auto-primes within 3 seconds of activation
  • Self-cleaning impeller design reduces clog risk
  • Thermal overload protection with auto-reset
  • Anti-vibration rubber mounting feet

Installation Requirement:

  • Disconnect power and water supply before replacement.
  • Mount using 4 M5 screws with rubber grommets — torque to 2.5 Nm.
  • Ensure drain hose is sloped downward at minimum 1 cm per meter.
  • Prime pump with 200ml water before first cycle if dry.

Usage Notes:

  • Check impeller monthly for coin, button, or fiber blockage.
  • Do not run pump dry — causes bearing seizure within 30 seconds.
  • Replace pump if noise exceeds 55 dB(A) — indicates bearing wear.
  • Use only original AEG pump — third-party pumps have incompatible impeller geometry and cause error codes.