Digital guide

You are here:

Woodward 9908-217

Product Name:​ LQ25 Liquid Fuel Metering Valve (Enhanced Configuration)
Product Overview:​ 9908-217 is an LQ25-series liquid fuel metering valve with refined metering characteristics. It adopts a rotary-plate metering structure integrating a Limited-Angle Torque (LAT) motor, frameless resolver feedback, and optional PIV / SOV interfaces.

Detailed content

Key Technical Specifications:
  • Metering Accuracy: ±5% of nominal flow or ±0.5% of maximum rated flow (larger value applies)
  • Full-Stroke Swivel Time: <100 ms
  • Shutoff Swivel Time: <50 ms
  • Shutoff Response (close): <100 ms
  • Maximum Fuel Inlet Pressure: 1,200 psig (8,274 kPa)
  • Nominal Metering ΔP: 50 psid (345 kPa)
  • Minimum Metered Flow: 80 lb/h (36 kg/h)
  • Turndown Ratio: >100:1
  • Fuel Filtration: ≤20 µm
  • Water Content: ≤0.1% by volume
  • Drive Voltage: 18–32 VDC
  • Command / Feedback: 4–20 mA
  • Ingress Protection: IP66
  • Operating Temperature: –28 °C to +85 °C
  • Storage Temperature: –40 °C to +103 °C
  • Fuel Connection: SAE J1926/1 threaded
Materials & Structure:​ The valve body and wetted components use corrosion-resistant materials or anti-corrosion treatment; seals are FKM fluoro-carbon rubber suitable for a wide range of liquid fuels. The overall structure is a rotary-plate metering design integrating a Limited-Angle Torque motor, frameless resolver feedback, and optional PIV/SOV mounting interfaces.
Working Principle:​ The drive unit receives a 4–20 mA position command and, through closed-loop control, drives the limited-angle torque motor to rotate the rotary plate, changing the metering port area. The patented single-stage droop-compensated differential pressure regulator holds the metering-port ΔP at approx. 345 kPa (50 psid), so that output flow is governed solely by port area, achieving precise metering.
Installation Requirements:​ Must be used with a positive-displacement fuel pump—not compatible with other pump types. Fix the valve to a rigid foundation via standard mounting holes; orient for ease of maintenance. Electrical connection is made through a single terminal block; use shielded cable between driver and valve body. Wear hearing protection on-site.
Usage Precautions:​ Fuel must be filtered to ≤20 µm with water content ≤0.1% by volume. Regularly check electrical-connection tightness and cable-shield integrity. Avoid long-term operation outside the specified temperature envelope. Before maintenance, cut fuel supply and confirm the system is depressurized.