Woodward 9908-202
Product Name: LQ25 Liquid Fuel Metering Valve (Standard Configuration)
Product Overview: 9908-202 is the baseline LQ25-series fully electric liquid fuel metering valve for industrial and aeroderivative gas turbines rated 1,000–42,000 kW. It couples an integrated brushless DC motor with a rotary shear-meter plate and a non-contact resolver feedback to deliver precise, repeatable fuel metering.
Detailed content
Key Technical Specifications:
-
Applicable Power Range: 1,000–42,000 kW
-
Maximum Fuel Inlet Pressure: 1,200 psig (8,274 kPa)
-
Maximum Fuel Bypass Pressure: 100 psig (690 kPa)
-
Nominal Metering ΔP: 50 psid (345 kPa)
-
Minimum Metered Flow: 80 lb/h (36 kg/h)
-
Turndown Ratio: >100:1
-
Fuel Filtration: ≤20 µm
-
Water Content: ≤0.1% by volume
-
Solid Sediment: ≤1.0 mg/L
-
Command / Feedback: 4–20 mA
-
Drive Voltage: 18–32 VDC
-
Full-Stroke Time: <100 ms
-
Metering Accuracy: ±5% of nominal flow or ±0.5% of max flow (larger value applies)
-
Weight: approx. 35 kg (77 lb)
-
Nominal Bore: 29.2 mm (1.15 in)
-
Ingress Protection: IP66
-
Operating Temperature: –28 °C to +85 °C
-
Storage Temperature: –40 °C to +103 °C
Functional Features: Single-moving-part rotary plate design, non-contact resolver (no mechanical wear), rare-earth PM motor for high torque density, remote emergency-shutdown input, valve/driver fault output. Self-cleaning shear metering resists contamination. No field calibration required—flow is factory-characterized.
Materials & Structure: Corrosion-resistant wetted materials, FKM seals, stainless steel internal hardware. Frameless single-speed resolver. Standard SAE threaded fuel ports, terminal-block electrical interface.
Working Principle: The driver converts the 4–20 mA command into motor current. The brushless DC motor rotates the metering sleeve, changing port area. The integral droop-compensated ΔP regulator holds 50 psid, making flow a direct function of port area.
Installation Requirements: Install on the discharge side of a positive-displacement pump. Keep bypass return line unobstructed. Use specified torque on standard fasteners. Ground shielded cable at a single point to prevent EMI. Position for easy inspection and maintenance.
Application Scenarios: Gas-turbine generator sets, industrial mechanical drives, marine propulsion liquid-fuel systems. Compatible with diesel, JP-series aviation fuel, kerosene, gasoline, and naphtha.
Usage Precautions: Maintain ≤20 µm filtration. Inspect electrical connections and cable insulation periodically. Wear hearing protection—the valve generates aerodynamic noise during operation. Avoid impact during transport/storage.