Maximum Fuel Inlet Pressure: 1200 psig (8274 kPa)
-
Maximum Fuel Bypass Pressure: 100 psig (690 kPa)
-
Rated Metering Differential Pressure: 50 psid (345 kPa)
-
Fuel Filtration: 20 μm or finer
-
Minimum Metering Flow: 36 kg/h (80 lb/h)
-
Flow Turn-down Ratio: > 100:1
-
Operating Temperature: -28°C to +85°C
-
Driver Power: 18–32 VDC
-
Command Signal: 4–20 mA
-
Position Feedback: 4–20 mA
-
Ingress Protection: IP66
Functional Features: Shear-type self-cleaning metering with integrated brushless DC actuator. Supports liquid fuel bypass function. Remote driver enables closed-loop position control and diagnostics.
Materials & Construction: Corrosion-resistant fuel-wetted components.
Applications: Industrial and aeroderivative gas turbine liquid fuel metering and bypass control in power generation, mechanical drive, and marine propulsion.
Installation & Notes: Install per Woodward LQ25T series documentation. Factory-calibrated.