3103 Series Electric Fuel Valve with EM35MR All-Electric Actuator
Product Introduction
The Woodward 8915-896 is a fully electric fuel metering valve assembly belonging to the 3103 valve family, driven by an EM35MR all-electric actuator. This configuration provides precise fuel metering for industrial gas turbines without requiring hydraulic oil supply, fundamentally eliminating hydraulic contamination and maintenance issues.

Detailed content

Technical Specifications
  • Pressure Rating: CE limited to 4964 kPa (720 psia); Enhanced version up to 6205 kPa gauge (900 psig)
  • Differential Pressure Range: 172 to 6205 kPa (25 to 900 psi)
  • Fuel Temperature: –40 to +149 °C
  • Ambient Temperature: –40 to +93 °C
  • Metered Fuel Types: Natural gas, propane, methane
  • Fuel Specific Gravity: 0.5 to 1.05
  • Fuel Filtration: 25 µm absolute (β = 75)
  • Flow Accuracy: ±5% of point or ±0.25% of maximum flow; ±2% of point for DLE applications
  • Minimum Differential Pressure: 172 kPa (non-DLE), 345 kPa (DLE at 50 psid)
  • Output Shaft Rotation: 60° (limited by mechanical stop)
  • Continuous Output Torque: ±24.9 N·m (±220 lb-in)
  • Peak Output Torque: ±62.4 N·m (±552 lb-in)
  • Clutch Disengagement Torque: ±68 N·m (±600 lb-in)
  • Torque Constant: 1.8 N·m/A (16 lb-in/A)
  • Motor Type: Brushless DC motor with samarium-cobalt permanent magnets bonded and encapsulated in rotor
  • Power Input: 28 Vdc nominal, 18 to 32 Vdc operating range
  • Current: Max 37 A (for 50 ms), max continuous 15 A
  • Slew Rate: 50° stroke — 150 ms opening, 80 ms closing (at 28 Vdc, room temperature)
  • Bandwidth: > 5 Hz
  • Position Accuracy: ±0.50° analog mode; ±0.10° digital mode (±6 arc-min RSS)
  • Resolver Accuracy: ±0.05°
  • Assembly Weight: Approx. 44 kg (96 lb)
  • Fuel Connection: 2-inch 600# ANSI B16.5 flange (50 mm, 2669 N)
Material Composition
  • Valve Body: Stainless steel
  • Internal Components: Fully hardened stainless steel throughout
  • Actuator Housing: Cast aluminum flameproof enclosure
  • Motor: Samarium-cobalt permanent magnet brushless DC motor
  • Resolver: Non-contact electromagnetic induction structure
  • Coupling: Stainless steel torsion coupling
Structural Features
  • Planetary gear reduction actuator directly coupled to valve body
  • High-precision brushless resolver directly coupled to metering sleeve for position detection
  • Inlet flow guide tube with redundant sealing design
  • Self-cleaning metering structure designed for sour (acidic) gas environments
Working Principle
The controller signal drives the motor to change the valve sleeve opening. The resolver provides feedback for closed-loop control. In case of fault, a spring closes the valve to the minimum fuel position.
Functional Features
  • Fully electric drive, no hydraulic oil source required
  • Brushless DC motor with samarium-cobalt magnets, all stator windings fully encapsulated
  • High-precision brushless resolver as non-contact position feedback, directly coupled to valve metering sleeve
  • Dual resolver configuration for redundant position detection
  • Built-in slip clutch protects transmission mechanism, disengages at 1.5× maximum actuator output force
  • Fault detection circuit monitors 4–20 mA interface, position controller, driver, and feedback status
  • Automatic motor power cut-off on fault or external trip command; valve springs to minimum fuel position
  • Analog driver accepts 4–20 mA demand signal; digital driver exchanges 16-bit digital position data via serial communication with NetCon/MicroNet systems
  • Flameproof cast aluminum enclosure compliant with ATEX Category 2
  • CSA certified: Class I, Division 1, Groups C, D; Class I, Division 2, Groups B, C, D (NRTL/C); LCIE Zone 1 Group IIB
Application Scenarios
  • Industrial gas turbine fuel metering and control systems
  • Applications where no hydraulic oil source is available or hydraulic oil is prohibited
  • Explosion-proof zones (Zone 1 / Division 1)
  • DLE high-precision control
  • Paired with Woodward NetCon and MicroNet systems
  • Power generation, chemical processing, oil & gas transmission, distributed energy
Installation Requirements
  • Flameproof cover plate bolts tightened to specified torque
  • Explosion-proof cable glands and conduit sealing
  • Use auxiliary equipment for lifting during handling
  • Proper grounding system connection
  • 25 µm absolute filtration at fuel inlet
Usage Notes
  • Motor cables must not be coiled
  • Maintenance in explosion-proof areas requires power disconnect
  • Regularly inspect cable connections
  • Protect against surface temperature hazards
  • Mechanical stops must not be adjusted
  • Inspect flexibility after prolonged shutdown