Woodward 8915-896
Product Name
3103 Series Electric Fuel Valve with EM35MR All-Electric Actuator
Product Introduction
The Woodward 8915-896 is a fully electric fuel metering valve assembly belonging to the 3103 valve family, driven by an EM35MR all-electric actuator. This configuration provides precise fuel metering for industrial gas turbines without requiring hydraulic oil supply, fundamentally eliminating hydraulic contamination and maintenance issues.
Detailed content
Technical Specifications
- Pressure Rating: CE limited to 4964 kPa (720 psia); Enhanced version up to 6205 kPa gauge (900 psig)
- Differential Pressure Range: 172 to 6205 kPa (25 to 900 psi)
- Fuel Temperature: –40 to +149 °C
- Ambient Temperature: –40 to +93 °C
- Metered Fuel Types: Natural gas, propane, methane
- Fuel Specific Gravity: 0.5 to 1.05
- Fuel Filtration: 25 µm absolute (β = 75)
- Flow Accuracy: ±5% of point or ±0.25% of maximum flow; ±2% of point for DLE applications
- Minimum Differential Pressure: 172 kPa (non-DLE), 345 kPa (DLE at 50 psid)
- Output Shaft Rotation: 60° (limited by mechanical stop)
- Continuous Output Torque: ±24.9 N·m (±220 lb-in)
- Peak Output Torque: ±62.4 N·m (±552 lb-in)
- Clutch Disengagement Torque: ±68 N·m (±600 lb-in)
- Torque Constant: 1.8 N·m/A (16 lb-in/A)
- Motor Type: Brushless DC motor with samarium-cobalt permanent magnets bonded and encapsulated in rotor
- Power Input: 28 Vdc nominal, 18 to 32 Vdc operating range
- Current: Max 37 A (for 50 ms), max continuous 15 A
- Slew Rate: 50° stroke — 150 ms opening, 80 ms closing (at 28 Vdc, room temperature)
- Bandwidth: > 5 Hz
- Position Accuracy: ±0.50° analog mode; ±0.10° digital mode (±6 arc-min RSS)
- Resolver Accuracy: ±0.05°
- Assembly Weight: Approx. 44 kg (96 lb)
- Fuel Connection: 2-inch 600# ANSI B16.5 flange (50 mm, 2669 N)
Material Composition
- Valve Body: Stainless steel
- Internal Components: Fully hardened stainless steel throughout
- Actuator Housing: Cast aluminum flameproof enclosure
- Motor: Samarium-cobalt permanent magnet brushless DC motor
- Resolver: Non-contact electromagnetic induction structure
- Coupling: Stainless steel torsion coupling
Structural Features
- Planetary gear reduction actuator directly coupled to valve body
- High-precision brushless resolver directly coupled to metering sleeve for position detection
- Inlet flow guide tube with redundant sealing design
- Self-cleaning metering structure designed for sour (acidic) gas environments
Working Principle
The controller signal drives the motor to change the valve sleeve opening. The resolver provides feedback for closed-loop control. In case of fault, a spring closes the valve to the minimum fuel position.
Functional Features
- Fully electric drive, no hydraulic oil source required
- Brushless DC motor with samarium-cobalt magnets, all stator windings fully encapsulated
- High-precision brushless resolver as non-contact position feedback, directly coupled to valve metering sleeve
- Dual resolver configuration for redundant position detection
- Built-in slip clutch protects transmission mechanism, disengages at 1.5× maximum actuator output force
- Fault detection circuit monitors 4–20 mA interface, position controller, driver, and feedback status
- Automatic motor power cut-off on fault or external trip command; valve springs to minimum fuel position
- Analog driver accepts 4–20 mA demand signal; digital driver exchanges 16-bit digital position data via serial communication with NetCon/MicroNet systems
- Flameproof cast aluminum enclosure compliant with ATEX Category 2
- CSA certified: Class I, Division 1, Groups C, D; Class I, Division 2, Groups B, C, D (NRTL/C); LCIE Zone 1 Group IIB
Application Scenarios
- Industrial gas turbine fuel metering and control systems
- Applications where no hydraulic oil source is available or hydraulic oil is prohibited
- Explosion-proof zones (Zone 1 / Division 1)
- DLE high-precision control
- Paired with Woodward NetCon and MicroNet systems
- Power generation, chemical processing, oil & gas transmission, distributed energy
Installation Requirements
- Flameproof cover plate bolts tightened to specified torque
- Explosion-proof cable glands and conduit sealing
- Use auxiliary equipment for lifting during handling
- Proper grounding system connection
- 25 µm absolute filtration at fuel inlet
Usage Notes
- Motor cables must not be coiled
- Maintenance in explosion-proof areas requires power disconnect
- Regularly inspect cable connections
- Protect against surface temperature hazards
- Mechanical stops must not be adjusted
- Inspect flexibility after prolonged shutdown