Digital guide

You are here:

Woodward 8915-889

Product Name
3103 Valve c/w TM55 Actuator (Electro-Hydraulic Fuel Valve Assembly)
Product Introduction
Based on available product records, the Woodward 8915-889 is identified as a used/surplus GE gas turbine part configured as a “3103 Valve c/w TM55 Actuator” — a 3103 series rotary fuel valve combined with a TM55 electro-hydraulic actuator. This assembly is intended for fuel metering and control in industrial gas turbine applications.

Detailed content

Technical Specifications
Detailed technical specifications for this exact part number (8915-889) were not available in the retrieved materials. For reference, the 3103 valve family with electro-hydraulic actuators typically features:
  • Valve Type: Rotary sleeve and gate metering structure (self-cleaning design)
  • Actuator: TM55 electro-hydraulic actuator with hydraulic servo piston
  • Hydraulic Supply: Turbine lube oil or dedicated hydraulic power unit
  • Fail-safe: Spring-return to minimum fuel position upon loss of power
Material Composition
  • Valve Body: Stainless steel precision casting
  • Internal Components: Fully hardened stainless steel
  • Metering Sleeve & Gate: Precision-ground, fully hardened stainless steel
  • Seals: High-temperature FKM or other fuel-compatible elastomers
Structural Features
  • Direct coupling between actuator and valve body, no intermediate linkage
  • Double-acting servo piston for high driving force
  • Optional electrical position feedback sensor (RVDT, accuracy ±0.16°)
Working Principle
The electronic controller sends an electrical command signal to the torque motor servo valve inside the TM55 actuator. The servo valve generates a pressure differential that drives the two-stage spool, regulating hydraulic oil flow to the double-acting servo piston. Piston movement rotates the output shaft, driving the 3103 fuel valve metering sleeve to change opening. An internal mechanical feedback mechanism re-centers the servo valve at the target position for precise proportional positioning. Upon power loss, the spring-loaded mechanism pushes the valve to the minimum fuel position for fail-safe protection.
Application Scenarios
  • Fuel metering and control for GE industrial gas turbines
  • Gas turbine generator sets in power plants
  • Mechanical-drive gas turbines for compressors and pumps
Installation Requirements
  • Care must be taken during handling to avoid damaging seals and factory calibration settings
  • Hydraulic and fuel connection ports must be protected with plastic plugs before final piping
  • Hydraulic supply pressure must meet specified range
  • Hydraulic system must be purged of trapped air
  • Fuel inlet requires a filter meeting cleanliness requirements
  • Shielded cable for electrical connections with proper grounding
Usage Notes
  • Hydraulic oil cleanliness is critical for actuator life
  • Fuel impurity: solid particles < 10 µm ≤ 30 ppm, > 10 µm ≤ 0.3 ppm
  • Regular inspection of hydraulic pressure, oil condition, and seal integrity
  • Overhaul at intervals recommended by Woodward OEM