Detailed content
- Supply Pressure: 2413 to 10 342 kPa (350 to 1500 psig)
- Flow Accuracy: 5.0% of point or 0.5% of maximum flow
- Filtration: 10 μm nominal, 20 μm absolute
- Temperature Range: 0 °C (32 °F) to 66 °C (150 °F)
- Material Composition: Stainless steel valve body; hardened stainless-steel replaceable sleeve; ceramic metering valve and regulator parts
- Structural Features: Variable-area-metering valve with contoured ports; single-stage delta-P regulator piston
- Working Principle: The metering plunger (driven by actuator) sets the port opening; the regulator piston senses and controls the pressure drop across metering ports so flow remains unaffected by variations in valve inlet or discharge pressures
- Applications: GE gas turbine water injection; NOx emission reduction; works with Woodward EM Digital Driver or 24 V DVP
- Installation Requirements: Install per Woodward 3151A Water Valve documentation; water supply must meet 10 μm nominal / 20 μm absolute filtration requirement
- Usage Notes: Read all related manuals before installation, operation, or service; do not modify or use outside specified operating limits; follow ESD precautions—avoid synthetic materials, do not touch PCB components directly; unauthorized modifications constitute misuse and void warranty