Digital guide

You are here:

Woodward 8915-843

  • Product Type: 3151A Water Valve
  • Core Function: Metered water bypass for gas turbine combustion chamber water injection
  • Medium: Water
  • Flow Rate: 3.8–250 L/min (1–66 US gal/min)

Detailed content

  • Supply Pressure: 2413–10 342 kPa (350–1500 psig)
  • Maximum Bypass Pressure: 345 kPa (50 psig)
  • Flow Accuracy: 5.0% of point or 0.5% of maximum flow
  • Filtration: 10 μm nominal, 20 μm absolute
  • Temperature Range: 0–66 °C (32–150 °F)
  • Material Composition: Stainless steel primary construction; replaceable hardened stainless-steel sleeve; ceramic on metering valve and regulator parts
  • Structural Features: Variable-area-metering valve; single-stage throttling delta-P regulator piston
  • Working Principle: Actuator-controlled metering plunger sets port opening; delta-P regulator maintains constant differential pressure across metering ports so flow remains unaffected by variations in valve inlet or discharge pressures
  • Applications: Industrial gas turbine NOx reduction; water injection control; compatible with Woodward EM Digital Driver or 24 V DVP
  • Installation Requirements: Install per Woodward 3151A outline drawings; ensure water supply meets filtration specification
  • Usage Notes: Do not operate beyond rated pressure/temperature limits; proper ESD handling required; unauthorized modification voids warranty and certifications