Digital guide

You are here:

Woodward 8915-628

  • Product Type: 3151A Water Valve (valve only / valve assembly depending on configuration)
  • Core Function: Metered bypass flow for high-pressure centrifugal-type pumps, providing pump-stability and heat-balance considerations
  • Medium: Water
  • Flow Rate: Minimum 3.8 L/min (1 US gal/min); Maximum 250 L/min (66 US gal/min)

Detailed content

  • Supply Pressure: 2413 to 10 342 kPa (350 to 1500 psig)
  • Maximum Bypass Pressure: 345 kPa (50 psig)
  • Flow Accuracy: 5.0% of point or 0.5% of maximum flow, whichever is greater
  • Water Filtration Requirement: 10 μm nominal, 20 μm absolute
  • Temperature Range: 0 °C (32 °F) minimum to 66 °C (150 °F) maximum (standard seal material)
  • Material Composition: Valve body primarily constructed of stainless steel; replaceable hardened stainless-steel sleeve in the drain flange area protects against cavitation; ceramic used on metering valve and regulator valve parts to prevent galling and resist erosion
  • Structural Features: Variable-area-metering valve with contoured ports at one end of the metering sleeve; single-stage throttling delta-P regulator piston; sleeve can be rotated in quarter-turn increments or replaced to extend valve life
  • Working Principle: The actuator positions the metering-valve plunger to open or close the contoured ports; the single-stage regulator piston senses and controls the pressure drop across the metering ports so flow remains unaffected by variations in valve inlet or discharge pressures
  • Applications: Gas turbine water/steam injection for NOx reduction; compatible with Woodward EM Digital Driver or 24 V DVP
  • Installation Requirements: Must be installed in accordance with Woodward outline drawings and the 3151A installation & operation manual; proper alignment with high-pressure centrifugal pump required
  • Usage Notes: Do not use outside specified mechanical, electrical, or operating limits; observe all electrostatic discharge precautions when handling associated electronic controls; unauthorized modifications constitute misuse and void warranty