Gas Filtration Requirement: 25 μm absolute
-
Gas Supply Pressure: 345 to 5,170 kPa (50 to 900 psig)
-
Ambient Temperature: –20 to +80 °C
-
Features: Compact and lightweight; optimized metering‑port geometry giving a precise flow‑vs‑lift relationship; standardized interface compatible with Woodward TM‑series and EM‑series actuators.
-
Applications: Small industrial gas‑turbine generator sets; CHP systems; distributed‑energy gas‑flow management; industrial gas‑engine fuel systems; marine and offshore small gas‑power units.
-
Working Principle: Gas enters through the inlet port, passes through the precision‑metered port, and exits to the combustion system; lift is driven externally by a mating actuator.
-
Note: Confirm the exact actuator configuration, sensor compatibility (e.g., DCSE‑750‑4000 or SQ‑2000‑531 linear position sensor), and port size against the Woodward order code suffix before deployment.