Woodward 8915-106
Product Name: 1907 Small Gas Valve
Product Introduction: The 8915-106 is a small gas valve of the Woodward 1907 series, designed for gas fuel metering in small and medium gas turbines and industrial gas engines, delivering reliable gas flow control in industrial power generation, mechanical drive and combined heat and power applications.
Detailed content
Technical Specifications:
-
Part Number: 8915-106
-
Manufacturer: Woodward
-
Series: 1907 Series
-
Device Type: Small Gas Valve / Gas Metering Valve
Functional Features:
-
High-precision gas flow regulation meeting turbine control requirements from start-up to full load
-
Metering port manufactured with precision process, with stable and excellent repeatability of flow characteristics
-
Compact and robust structure suitable for high-vibration and space-constrained dynamic environments
-
Standardized interface design for easy integration with TM series, EM series and other actuators
-
Proven sealing technology ensuring safe and leak-free gas system
Application Scenarios:
-
Small and medium industrial gas turbine generator sets
-
Combined heat and power and distributed energy systems
-
Gas engine fuel management systems
-
Marine and offshore platform gas power plants
-
Precise gas metering and control in industrial processes
Performance Parameters:
-
Working Medium: Natural gas, treated clean gas fuel
-
Gas Filtration Requirement: 25 micron absolute
-
Working Pressure Range: Complies with industrial gas system standard specifications
-
Flow Capacity: Matches full operating conditions of small and medium turbine engines
-
Ambient Temperature Adaptation Range: -20°C to +80°C
Material Composition:
-
Valve Body: Aviation-grade aluminum alloy or stainless steel precision casting
-
Metering Spool: Surface-hardened wear-resistant alloy steel, precision lapped
-
Sealing Elements: Gas-resistant fluorocarbon rubber (FKM) composite material
-
Connection Fasteners: High-strength corrosion-resistant alloy steel
Structural Features:
-
Precision metering port with accurate functional relationship between flow and opening
-
Standard flange or threaded connection ports for easy pipeline system integration
-
Actuator mounting interface precision machined to ensure coaxiality
-
Smooth internal flow passages reducing turbulence, noise and pressure loss
-
Overall structure validated for anti-vibration and shock resistance, adapting to long-term operation of power plants
Working Principle: The actuator receives electrical signals from the control system and produces mechanical displacement, driving the spool to change port opening, thereby precisely controlling gas flow. The control system adjusts valve position in real time based on turbine speed, load demand, exhaust temperature and other parameters, ensuring the turbine receives appropriate fuel. The valve design ensures a deterministic and highly repeatable correspondence between flow and opening.
Installation Requirements:
-
Flow direction and installation orientation comply with valve body markings and design specifications
-
Configure gas filtration devices of required specification upstream and downstream of valve body
-
Select location facilitating actuator installation and electrical wiring
-
Piping system shall have independent support to avoid stress transmission to valve
-
Complete purge, leak detection and full-stroke test before system commissioning
Usage Precautions:
-
Maintain gas cleanliness; perform regular filter system maintenance
-
Follow gas system safety operating and explosion-proof regulations
-
Regularly inspect external valve sealing and connection fastener condition
-
Prohibit long-term operation under over-pressure, over-temperature or severe pulsation conditions
-
Seal inlet and outlet when in long-term storage; keep in dry environment