Detailed content
Technical Specifications
Inputs: 24 x DC24V, opto-isolated
Outputs: 16 x relay, 2 A per point resistive
Total I/O: 40 points
Program capacity: 12 k steps
Basic instruction speed: 0.3 µs/step
Sensor power: 24 VDC, 400 mA
High-speed pulse: 6 channels, 50 kHz
Communication: 1 x RS485, Modbus RTU, ECbus
Expansion: up to 4 modules
Power input: 85-264 VAC, 50/60 Hz
Dimensions: 182 x 90 x 75 mm
Functional Features
Relay outputs for valves, contactors and small loads
High-speed counting
Pulse output for simple positioning
Modbus master/slave communication
Application Scenarios
Packaging machines
Textile equipment
Small production lines
OEM machinery control
Working Principle
Scans inputs, executes user program, updates outputs, and exchanges data over RS485 or expansion bus.
Installation Requirements
DIN rail or panel mounting
Separate power and load wiring
Allow ventilation space
Usage Notes
Relay outputs have mechanical life limits.
Do not exceed 2 A per output point.
Use snubber circuits for inductive AC loads.