Technical Specifications:
-
Element: PT1000 (1000 Ω at 0 °C)
-
Range: -50 to +200 °C
-
Accuracy: ±0.1 °C (0–100 °C)
-
Signal: 4–20 mA (with transmitter) or raw resistance depending on harness
-
Supply: 12–24 VDC (if active)
-
Sealing: IP65 probe head
-
Response: ~3 s
-
-
Functional Features: Direct drop-in to AKM/PMA stator pocket, links to drive thermistor input or external PLC analog input.
-
Application Scenarios: Overheat protection for AKM43/52, PMA large motors, continuous-duty machine tools.
-
Structural & Material: Stainless sheath, PTFE leads, molded connector.
-
Installation Requirements: Insert into designated stator hole; do not crimp leads; keep away from windings electrically.
-
Usage Notes: TTB prefix in Kollmorgen legacy = temperature transducer/bracket; confirm 2-wire vs 3-wire wiring against drive thermistor input.