Digital guide

You are here:

Kollmorgen S70301-NANANA-02US

Product Overview

1.8kW rated single-axis high voltage servo drive, US regional electrical standard variant of S703 platform, calibrated for 480V 60Hz North American industrial grid, equipped with UL safety certification, matched for medium-frame AKM servo motors. Retains full S700 series shared DC bus and SIL3 safety architecture.

Detailed content

Core Technical Specifications

  1. Input Power Rating: Three-phase 380–480 VAC, 60 Hz US standard grid
  2. Continuous Output Current: 9 Arms RMS
  3. Peak Output Current: 18 Arms RMS (3-second 200% overload)
  4. Nominal S1 Apparent Power: 1.8 kVA
  5. DC Bus Max Voltage: 900 VDC
  6. Control Loop Timing: Current loop 0.5 μs; Speed loop 31.25 μs; Position loop 62.5 μs
  7. Communication Configuration: EtherCAT, CANopen, Modbus TCP (NANANA = No optional fieldbus add-on boards)
  8. Region Code Definition: 02US = UL Listed, North American wiring terminal standard, 60Hz factory default parameter set
  9. Feedback Support: EnDat, BiSS, resolver, SFD, sine/cosine encoders
  10. Physical Dimensions: 70 mm (W) × 305 mm (H) × 243 mm (D)
  11. Net Weight: 3.9 kg
  12. Environmental Rating: IP20 cabinet mounting; Operating temperature 0°C ~ +45°C; UL508A industrial control certified

Function Features

  1. Position, velocity, torque three independent closed-loop control modes
  2. STO Safe Torque Off SIL3 safety function compliant with US OSHA machine safety standards
  3. Embedded electronic gearing, cam curve, flying cut synchronization functions
  4. Adaptive load inertia identification and auto vibration suppression filter
  5. 24-channel isolated digital I/O with high-speed position capture input
  6. Shared DC bus parallel connection capability for multi-axis energy recycling
  7. Complete hardware fault protection suite: Overcurrent, overvoltage, phase loss, overheat, encoder failure, short circuit
  8. MotionEngine standalone programming without external motion controller

Performance Highlights

  1. Optimized 60Hz grid power factor correction circuit for North American factory power distribution
  2. UL safety certified internal power circuit for US machinery export compliance
  3. High dynamic response speed loop bandwidth up to 1.2 kHz
  4. Standard EtherCAT bus enables high-speed multi-axis synchronous linkage

Material & Structural Characteristics

  1. Heat sink: Aluminum alloy vertical fin extrusion
  2. Cabinet frame: Galvanized steel sheet with anti-rust passivation coating
  3. Power terminals: US standard screw-clamp copper terminals compatible with AWG wire gauge
  4. Signal connectors: Shielded D-SUB connectors with EMI suppression gaskets
  5. PCB substrate: FR-4 high-temperature board with moisture-proof conformal coating

Working Principle

Three-phase 480VAC US mains rectified to high-voltage shared DC bus; IGBT power module converts DC to variable frequency three-phase sinusoidal PWM output driving permanent magnet servo motor. Encoder real-time position feedback forms triple closed-loop control. Regenerative energy shared between parallel axes via DC bus link; excess energy consumed via external braking resistor. Dual-channel STO safety circuit complies with US machine safety regulations to cut motor torque instantly during emergency stop trigger.

Applicable Industries

North American export packaging machinery, CNC metal cutting equipment, automated assembly lines, food processing machinery, hydraulic press servo retrofit systems, woodworking automation equipment

Installation Requirements

  1. Vertical wall mounting inside UL508A certified electrical cabinet, horizontal installation prohibited
  2. Minimum 80 mm vertical clearance above and below drive for heat dissipation
  3. Power wiring adopts AWG copper shielded cable, 360° shield grounding at cabinet PE bar
  4. Shared DC bus wiring follow AWG cross-section specifications defined in US manual
  5. For continuous full-load operation above 35°C ambient, cabinet forced air cooling mandatory

Operation Precautions

  1. Factory default parameter set to 60Hz grid; do not switch to 50Hz without re-calibration
  2. All safety circuit wiring must satisfy UL Class 1 control circuit standards
  3. Hot plugging of power and feedback connectors during energization strictly forbidden
  4. Annual heat sink dust removal maintenance required to prevent thermal overload
  5. Export equipment must retain original UL certification labels intact