Digital guide

You are here:

Kollmorgen S61400-PB

Product Series: S61400 (Encoder Housing & Accessories)

Product Introduction:
The S61400-PB is a rear-end protection cap (end bell cover) designed for Kollmorgen S-series absolute encoders. It protects the rear shaft-side bearing and encoder electronics from dust, moisture, and mechanical damage in harsh industrial environments.

Detailed content

Model Breakdown:

  • S61400 = Product Family (Encoder Accessory — Rear Cap)
  • PB = Configuration Code: Protection Cap with Bore Seal (standard variant)

Technical Specifications:

Parameter Value
Compatible Encoder Series Kollmorgen S61000 / S700 / S400 Series Absolute Encoders
Material Anodized Aluminum 6061-T6
Surface Finish Black Anodized (RAL 9005)
Bore Diameter Matches encoder shaft: typically 6mm or 8mm (model-specific)
Seal Type Lip Seal (NBR rubber, 70 Shore A)
IP Rating (Installed) IP65 (with seal engaged)
Operating Temperature -20°C to +80°C
Weight Approx. 0.08 kg
Mounting Method Press-fit or set-screw (M3×0.5)

Functional Features:

  • Protects encoder rear bearing from contaminant ingress (dust, oil mist, coolant).
  • Maintains IP65 environmental protection when installed on compatible encoders.
  • Lip seal prevents lubricant leakage and external contamination.
  • Lightweight aluminum construction adds minimal inertia to the system.

Structural Features:

  • Cylindrical housing with O-ring groove for secondary sealing.
  • Set-screw hole (M3) for locking to encoder housing.
  • Drain hole (if applicable) to prevent pressure buildup.

Applicable Industries:

  • Metal cutting (CNC mills, lathes)
  • Press machines
  • Welding robots
  • Food and beverage (washdown environments)
  • Woodworking machinery

Installation Requirements:

  • Clean encoder rear face before installation.
  • Apply thin film of grease (e.g., Klüber Isoflex NBU 15) on O-ring groove.
  • Press-fit or tighten set-screw to 0.5 Nm torque.
  • Verify shaft rotates freely after installation — no binding.

Usage Precautions:

  • Do not use on encoders without rear bearing — will not seal properly.
  • Replace seal if encoder has been submerged in coolant for extended periods.
  • Do not over-tighten set-screw — risk of housing deformation.