Product Name:​ SERVOSTAR S600 Single-Axis Digital Servo Drive with PROFIBUS Card
Product Introduction:
Legacy S600-series amplifier (now serviced-only, not recommended for new designs). Three-phase 230–480 VAC direct line operation, 6 A RMS continuous per phase, factory-fitted PROFIBUS DP interface card.

Detailed content

Technical Specifications:
  • Supply Voltage:​ 3 × 208–480 VAC (−10 % / +10 %), 50/60 Hz
  • Continuous Output Current:​ 6 A RMS/phase
  • Peak Output Current:​ 12 A RMS/phase (5 s)
  • DC Link Voltage:​ 260–675 VDC
  • Integrated Braking Resistor:​ Up to 200 W continuous (internal), external up to 1.5 kW continuous / 21 kW peak
  • Integrated Mains Filter:​ Up to 20 A
  • Communication:​ PROFIBUS DP (via factory-installed PB card), CAN (X6), RS232/PC setup (X6)
  • Feedback Supported:​ Resolver (2- to 36-pole), incremental encoder, sin/cos encoder, EnDat, Hiperface, BiSS, ComCoder
  • Control Functions:​ Position controller with 255 motion blocks, speed profiles, registration control, jerk limiting, absolute/relative moves, multiple homing modes, electronic gearing, master-slave
  • Digital I/O:​ 4 × 24 VDC inputs, 2 × open-collector outputs (X3)
  • Analog I/O:​ 2 × ±10 V inputs, 2 × ±10 V outputs (X3)
  • Protection:​ IP20 (cabinet use only)
  • Certifications:​ CE, UL, cUL
  • Dimensions (W×H×D):​ 100 × 275 × 265 mm (273 mm with connectors)
  • Operating Temp:​ 0–45 °C (derating above 40 °C)
Functional Features:
  • Intelligent onboard motion sequencing (no higher-level PLC needed for simple tasks)
  • Multi-feedback auto-configuration through Kollmorgen GUI/setup software
  • Daisy-chain motion tasks and reference-traverse modes
  • Shielded cable termination directly on amplifier body
Installation Requirements:
  • Vertical mounting on grounded metal panel inside 300 mm switch cabinet
  • Top/bottom clearance ≥ 40 mm, side clearance ≥ 75 mm (S300-class guidance; S600 similar)
  • 24 VDC control supply required
  • Proper 3-phase fusing and mains filter if external wiring exceeds 25 m
Use Notes:
  • Not for new machine designs; S700/AKD is the replacement path
  • Residential-area use may require additional EMI filtering
  • PROFIBUS address set via DIP switches or software