Digital guide

You are here:

Kollmorgen S30361-NA-SB

Product Introduction:
S30361-NA-SB is the 3 A RMS variant of the S300 family, accepting 110–230 VAC single/three-phase and driving brushless synchronous servo motors, async motors, or linear motors. NA = no base-fieldbus card (plain I/O + RS-232); SB = specific connector/option configuration. S300 is the last generation before S700/AKD and still widely supported for retrofits.

Detailed content

Technical Specifications:
  • Supply:​ 110–230 VAC (1Φ or 3Φ), 50/60 Hz
  • Continuous current:​ 3 A RMS
  • Peak current:​ 9 A RMS
  • Max DC bus:​ 450 VDC
  • Continuous power:​ ~0.7 kVA
  • Current loop bandwidth:​ 250 kHz
  • Velocity loop gain:​ 0.1–100 A/RPM
  • Position loop gain:​ 0.1–100 Hz
  • Feedback supported:​ Resolver, incremental encoder, SinCos 1 Vpp, EnDat 2.1/2.2, BiSS, SSI, SFD, Hiperface DSL (via card)
  • Fieldbus options:​ CANopen, DeviceNet, Profibus, Sercos II, EtherCAT (add-on cards)
  • I/O:​ 6–8 digital in, 2–3 digital out, 1 analog in, 1 analog out, STO inputs
  • Safety:​ STO (Safe Torque Off) capable, PFHd ~1.5×10⁻⁷ /h
  • Dimensions:​ 70 mm W × 270 mm H × 171 mm D
  • Weight:​ 2.6 kg
  • Protection:​ IP20
  • Operating temp:​ 0–40 °C (2.5%/°C derate to 55 °C)
Functional Features:
  • DSP three-loop control with interactive Bode tuning (DriveGUI)
  • Auto-commutation with Kollmorgen AKM/6SM/Goldline
  • Flash-stored parameters, ASCII command interface
  • Expandable I/O and fieldbus via daughter cards
  • Built-in regen management, external resistor supported
Material & Structure:
  • Press-formed steel chassis, anodized heatsink top
  • Control board + power board stacked
  • Front: 9-pin D-sub (RS-232), 15-pin D-sub (encoder), screw terminals (power/I/O)
Working Principle:
Mains rectified to DC bus; 3-phase IGBT output modulated by space-vector PWM; rotor position from selected feedback device; STO cuts gate drive when 24 VDC enable drops.
Application Scenarios:
Packaging machines, converting lines, semiconductor handlers, medical motion platforms, retrofit of SERVOSTAR CD/SR with modern tuning and safety.
Installation Requirements:
  • Vertical mount on conductive ground plate, ≥40 mm top/bottom, ≥75 mm side clearance
  • Copper conductors only, sized per IEC 60204
  • Feedback shielded twisted pair, separated from power cables
  • 24 VDC STO supply from safety relay, not from drive logic
Usage Notes:
S30361 = 110–230 V class; do not feed 400 VAC. NA means no factory bus card — add OPT-EC/OPT-PB3 if networking needed. SB defines North-America labeling and connector set; firmware upgradable but STO cert depends on firmware.