Digital guide

You are here:

Kollmorgen M01207MCEC0000

Product Name:​ AKD Series Multi-Axis Master Servo Drive with Motion Controller (likely AKD-M01207-MCEC-0000 derived)
Product Introduction:​ The part M01207MCEC0000 strongly corresponds to an AKD-series​ drive (specifically AKD-M01207-MCEC-0000), which is a 12 A, 3-phase, 240–480 VAC input servo drive with an integrated motion controller (0.8 GHz motion card) and internal regenerative resistor, configured as a multi-axis master drive.

Detailed content

Technical Specifications:
  • Rated Current:​ 12 Arms continuous
  • Rated Output Power:​ 8 kW / 8000 W
  • Supply Voltage:​ 240 / 380 / 400 / 415 / 440 / 480 VAC (3-phase)
  • Motion Controller:​ Integrated 0.8 GHz processor
  • Regenerative Braking:​ Internal resistor included
  • Feedback Support:​ Sine/Cosine encoder, EnDat 2.1/2.2, BiSS, HIPERFACE, resolver, SFD
  • Fieldbus:​ EtherCAT, CANopen, Modbus/TCP, PROFINET RT, EtherNet/IP (depending on EC code)
  • Protection:​ IP20
  • I/O:​ 13 × digital inputs (24 VDC), digital outputs, analog I/O options via expansion
  • Connectors:​ Detachable screw terminals (power, brake), D-Sub (feedback), RJ45 (EtherCAT/Ethernet), RJ25 (CAN)
    Functional Features:
  • Integrated PLC/motion engine for standalone multi-axis coordination without external controller.
  • High-speed EtherCAT communication for deterministic real-time control.
  • Automatic full-frequency auto-tuning wizard.
  • Safe Torque Off (STO) functionality.
  • Expandable with NVRAM, additional I/O cards, and processing modules.
    Structural Characteristics:
  • Modular book-style design with side-mounted power terminals and front-facing signal connectors.
  • Integrated heat sink with intelligent fan control (model-dependent).
  • DIN-rail or panel mount with adjacent unit stacking capability.
    Application Scenarios:
  • Complex multi-axis packaging machines, robotic cells, printing presses, material forming systems requiring centralized motion control.
    Installation & Usage Notes:
  • Requires proper 3-phase grounding and isolation; PE conductor must be securely connected.
  • Internal regen resistor has energy dissipation limits; large inertial loads may still require external regen clamp.
  • Firmware must be compatible with slave drives in the EtherCAT/CAN network.
  • Ensure ambient temperature remains within 0–40 °C (or per derating curve) and allow airflow clearance.

You may also like