Digital guide
You are here:
- Home
- Kollmorgen
- Kollmorgen LE10565
Detailed content
Product Overview:
The LE10565 is a pre-assembled motor power cable manufactured by Kollmorgen for use with AKM and AKM2 series servo motors. It features pre-terminated connectors on both ends, factory-tested for continuity and insulation resistance, and is optimized for EtherCAT-driven servo systems.
Technical Specifications:
| Parameter | Value |
|---|---|
| Cable Type | Servo Motor Power Cable, 4-conductor + 2 shield + 2 brake |
| Conductor Size | 3× 1.5mm² + 1× 0.75mm² (power) + 2× 0.5mm² (brake) |
| Conductor Material | Oxygen-Free Copper (OFC), Class 5 per IEC 60228 |
| Insulation Material | XLPE (Cross-Linked Polyethylene) |
| Shielding | Braided copper shield, 85% coverage |
| Outer Jacket | PUR (Polyurethane) — oil and abrasion resistant |
| Voltage Rating | 300/500V AC |
| Current Rating | 15A continuous (per conductor) |
| Motor-End Connector | M23 12-pin, straight, IP67 |
| Drive-End Connector | M23 12-pin, straight, IP67 (AKD-compatible) |
| Cable Length | 5 meters (standard for LE10565) |
| Operating Temperature | -20°C to +80°C (flexing), -40°C to +105°C (fixed) |
| Bend Radius (Min.) | 5× cable outer diameter (~35mm) |
| Weight | ~0.65 kg |
| Compliance | CE, UL, CSA, RoHS, REACH |
Structural Features:
- Pre-terminated — eliminates field termination errors
- Braided shield provides >60dB EMI attenuation at 100 MHz
- PUR jacket resists cutting fluids, hydraulic oil, and abrasion
- Integrated drain wire for shield grounding
Advantages:
- Factory-tested — guarantees correct pinout and insulation integrity
- PUR jacket rated for washdown and oily environments (IP67 at connectors)
- Pre-terminated M23 connectors save 30+ minutes of installation time per axis
- Matched impedance reduces reflection-induced motor heating
Applicable Industries:
All AKD/AKM servo applications — CNC, Robotics, Packaging, Semiconductor, Food & Beverage
Installation Requirements:
- Route cable away from high-current power lines (minimum 100mm separation)
- Connect shield drain wire to chassis ground at both ends (for EMC compliance)
- Do not exceed minimum bend radius — permanent conductor damage occurs below 3× diameter
- Torque M23 connector nuts to 8 Nm (do not use impact driver)
Usage Notes:
- This cable is motor-specific — verify motor frame size matches cable current rating
- Do not cut or modify cable — voids UL/CE certification
- For lengths other than 5m, order custom LE part number (do not splice)
- Brake wires (brown/blue) carry 24V DC — do not connect to motor power phases