Conductor Size: 6 AWG (16 mm²) — Typical for this Part Number Range
Conductor Count: 4 Core (3 Phase + Protective Earth)
Shielding: Braided Copper Shield
Outer Jacket Material: PUR (Polyurethane)
Rated Voltage: 600 V
Rated Current: 46 A (Typical for 6 AWG in this Configuration)
Operating Temperature: -20°C to +80°C
Connector End A: Drive-Side Connector (Integrated or Field-Attachable)
Connector End B: Motor-Side Connector (Integrated or Field-Attachable)
Bend Radius (Min.): 5× Cable Diameter (Static), 10× Cable Diameter (Dynamic)
Key Features:
- Pre-Assembled Cable with Terminated Connectors
- Low Inductance Design for Fast Current Transients
- EMI Shielded for Noise-Sensitive Environments
- UL Listed / CE Marked
Applicable Industries: All Kollmorgen AKD/AKD-T Drive to AKM/WKS Motor Connections
Installation Requirements: Use Dedicated Cable Tray Separate from Signal Cables, Ground Shield at Both Ends, Do Not Exceed Rated Current